Eramco Dust Free 3000 Series Скачать руководство пользователя страница 1

Save This Manual For

Future Reference

Installation

and

Service

Manual

Read ALL

INSTRUCTIONS

carefully.

Part No. 775-0299-497 Rev. 1C

Eramco • PO Box 519 • Royse City, TX 75189-0519 • 1-972-635-9565

Series 3000

This manual is copyright protected by ERAMCO. Any reproduction of this manual, in part or full, without the written permission of ERAMCO,

constitutes a violation of the U.S. copyright laws and is subject to prosecution.

©Printed in the U.S. by the Graphics Productions Department of ERAMCO, 1998.

Air Cleaners

Содержание Dust Free 3000 Series

Страница 1: ...oyse City TX 75189 0519 1 972 635 9565 Series 3000 This manual is copyright protected by ERAMCO Any reproduction of this manual in part or full without the written permission of ERAMCO constitutes a violation of the U S copyright laws and is subject to prosecution Printed in the U S by the Graphics Productions Department of ERAMCO 1998 Air Cleaners ...

Страница 2: ...ided along the right side of the unit for servicing the filters motor or blower The unit comes standard with a 5 HP motor with 7 5 HP motor available as an option Other options include vertical air discharge Inlet Outlet plenums roof mounting I beams and insulated weather tight cabinets A wide assortment of filter options are also available Refer to the replacement parts list at the end of this ow...

Страница 3: ...he equipment Call the factory if the distributor dealer is not available UNIT LOCATION 3 Multi Unit Configuration Dual Unit Configuration Single Unit Configuration Top view of room Top view of room Top view of room Place unit no less than 12 feet from wall Place unit no less than 12 feet from wall Place unit no less than 12 feet from wall No less than 25 of room length No less than 25 of room leng...

Страница 4: ...and extra care taken to prevent the accidental dislodging of internal duct insulation in the transition Take note of the side clearance required to access blower motor and drive belts and the space required to replace the filters Recommended minimum side clearance is 25 on the door side and 12 on the power side The Series 3000 can be wired for 230 or 460 line voltage Typical running amps at 230 vo...

Страница 5: ...utside of the joint to cover the gasket and to assist in developing an air and water tight joint ASSEMBLY Verify that the electrical service is the correct voltage current capacity and phase as listed on the unit nameplate Refer to the wiring diagram and verify that the motor and the control transformer are wired correctly Install an electrical disconnect to ensure safe servicing of the unit and e...

Страница 6: ...g collar To replace the collar push it against the inner race of the bearing turn the collar in the direction of the shaft rotation until tight then tighten the set screws Tightening the locking collar in the direction of the fan rotation will result in further tightening of the collar should the set screw work loose FAN WHEEL ADJUSTMENT If the fan is not centered in the scroll and or is rubbing a...

Страница 7: ...ree 3 inches away from the bottom to allow operation of the bottom door latches If 4 x4 timers are used be sure that they are both long enough to support the weight and oriented so as to transfer the weight of the unit to the underlying support structure If attachment to the support structure is required the floor or back side may be field drilled for bolts or screws Seal all penetrations with sil...

Страница 8: ...ir leaks Place bolts or screws where they will not interfere with filter insertion or removal Take care to locate the duct work so that the filter and motor are easily serviced Locate and shim the support beams or pads so they equally support the load PAD MOUNT The unit should be supported on beams or pads that are high enough that water cannot rise to the bottom of the unit and damage the filters...

Страница 9: ...lm must be removed prior to operation Remove the filter cabinet door and slide out the adsorbent filter tray Remove the screws that hold the end panel in place and remove the end panel Slide the individual adsorbent filters from the tray remove the protective wrap and place the filters back into the adsorbent filter tray Replace the end panel and the screws Repeat the process for the remaining fil...

Страница 10: ... 95 Ashrae short pocket V bag Set of 2 used with sorbent panels 98 D O P LW bank Set of 2 Refillable sorbent media panel empty 1 120 lbs bulk Charcoal for refill 150 lbs bulk Permanganate for refill 5 HP blower motor 7 5 HP blower motor Drive belt 95 D O P mini pleat Set of 2 99 97 D O P Hepa Set of 2 5 w g Magnahelic gauge 50 ft tubing for Magnahelic gauge Ozone generator grid plate 1 24V remote ...