- 12 -
APPENDIX A
ROOSEVELT FIRE DEPARTMENT STANDARD OPERATING PROCEDURE
TITLE:
PYROCAP B-136™ INITIAL FIRE ATTACK
PURPOSE:
TO ESTABLISH A METHOD FOR EMPLOYING PYROCAP B-
136™ IN INITJAL FIRE ATFACK OPERATIONS
APPLICATION:
THIS PROCEDURE WILL BE USED FOR ANY STRUCTURAL FIRE, TIRE
FIRE, AND FOR ANY VEHICULAR FIRE WHICH EXPOSES ANY STRUCTURE
TO INVOLVEMENT IN A FIRE
PERSONNEL REQUIRED:
3 FIREFIGHTERS AND 1 CHAUFFEUR/PUMP OPERATOR
EQUIPMENT REQUIRED:
1- PYROCAP B-136™ PRECONNECT LINE
1- 95 GPM IN-LINE EDUCTOR SET AT 3 PERCENT
3- 5 GAL. CANS PYROCAP B-136™ ADDITIVE
DEFINITION:
Pyrocap Line-
A 10 FOOT, 1-3/4 INCH HOSE CONNECTED TO THE PUMP OUTLET
WITH A 200 FOOT LENGTH OF 1-3/4 INCH HOSE ATTACHED TO A
TASK FORCE NOZZLE STORED IN CROSS LAY #1.
A. EVOLUTION USING AN EDUCTOR:
1.
Upon arrival, the fire engine will stop at the hydrant closest to the fire. Fire
fighter #1 will get off and rap the hydrant.
2.
The engine will lay a supply line to the scene of the fire.
3.
The chauffeur/pump operator will set up the engine to the pump.