INSTALLATION AND
OPERATING MANUAL
Version 1.0
VALIANT
Solar Siren Alarm Kit
Страница 1: ...INSTALLATION AND OPERATING MANUAL Version 1 0 VALIANT Solar Siren Alarm Kit ...
Страница 2: ...ERA VALIANT Red Lens DoP No EM0017 ...
Страница 3: ...ion of ERA Home Security Disposal and Recycling Disposal of this product is covered by the Waste Electrical or Electronic Equipment WEEE Directive It should not be disposed of with other household or commercial waste At the end of the product s useful life the packaging and product should be disposed of via a suitable recycling centre Please contact your local authority or the retailer from where ...
Страница 4: ...your product 2 2 PCB Layout 2 3 Installation 4 1 Positioning 4 2 PCB Layout 4 3 Jumper Setup 4 4 Usage 4 5 Installation 4 6 Jamming Detection 6 Notes 12 ERA Product Guarantee 13 5 Specification 4 Solar Charged Siren 3 1 Get to know your product 3 2 Buttons Functions 2 Magnetic Door Window Sensor 3 Remote Control Kit Contents 3 3 3 3 4 4 4 4 5 5 6 6 7 7 7 8 8 8 8 9 10 10 11 Page 2 ...
Страница 5: ...acket Slot 5 Self adhesive pad fixing markers Flashes every 2 seconds Self testing state Flashing twice Self testing finished enters working mode Flashes once Movement is detected Flashes once every 3 seconds Low battery indication immediate battery change required 1 1 Get to know your product KIT CONTENTS 1 PIR MOTION DETECTOR 1 2 3 4 5 1 2 LED Indication Page 3 ...
Страница 6: ...of the PIR The LEDs will then flash once when movement is detected for up to 3 minutes 3 2 1 2 1 Infrared Sensor Detects movement and triggers an alarm signal when the system is armed Tamper Switch If the casing is opened when in working state the tamper switch will be triggered and generate an alarm signal 1 3 PCB Layout 1 5 Working Mode 1 4 Test Mode AA 1 5V LR6 Infrared Sensor Zone Setting Tamp...
Страница 7: ...the room The LED indicator will flash once when motion is detected 2 a b 2m Status Indicator Magnet Transmitter Suitable for fitting to doors windows and any object that opens and closes The Window door sensor transmits a signal to the control panel siren when contact is broken between the transmitter and the magnet Transmits a low battery signal to the ERA alarm control panel Where possible mount...
Страница 8: ...o the back of the transmitter Peel off the other side of each adhesive strip Mount the magnet on the door and the transmitter on the door frame with less than a 1cm separation between the two When opening the door a small red indicator lights up briefly this indicates that the transmitter has sent a signal to the control panel 2 3 Installation 4 3 2 1 Tamper Switch Battery Zone Setting Note Please...
Страница 9: ...ute Disarm Press to arm the control panel siren and all of the accessories Full Arm Press to disarm the system Press to part arm the alarm system for systems with control panels only Press to activate the panic alarm SOS Press to arm the system with the solar siren in muted silent mode Press to disarm the system with the solar siren in mute silent mode Note 1 For Mute Arm Mute Disarm operation pre...
Страница 10: ...hich is relatively inaccessible to an intruder The Siren is designed to work on any aspect wall however for optimum performance try to avoid installing on a north facing wall or to a wall with shadows cast by other buildings trees and roof overhangs For optimum radio signal reception mount the Solar Siren to Maximum distance of one metre from any external or internal metalwork drainpipes gutters r...
Страница 11: ...ion of an alarm event Connecting to a Control Panel 5 4 3 2 1 When installed as a Siren only Alarm System without a Control Panel all of the Alarm Accessories must be registered to the Siren Connecting a Wireless Accessory to the Siren Press the Learn Button on the Solar Siren 0 5 seconds the system goes into Learn Mode after one beep is heard Press the Test Button on the Accessory or trigger the ...
Страница 12: ...ry has been successfully connected with the Siren Press on the Remote Control to exit Learn Mode it will emit one beep The System is now Armed press Unlock to Disarm the System Enter Exit Learning Status using a connected Remote Control 4 6 5 3 2 1 Test Mode prevents the Siren s tamper switch from triggering an alarm during maintenance or when changing the battery When the Remote Control is connec...
Страница 13: ...rea 25kg 433MHz ABS Plastic Temperature 10 C 55 C Humidity 80 non condensing Detector 100mm x 59mm x 43mm Transmitter 52mm x 30mm x 26 5mm Model No Back Up Power Start Up Power Solar Panel Output Current Standby Current Maximum Alarm Current Standby Time Maximum Siren Volume Receiving Distance Radio Frequency Housing Material Operation Conditions Dimensions L x W x H Model No Power Supply Standby ...
Страница 14: ...rective It should not be disposed of with other household or commercial waste At the end of its useful life the packaging and product should be disposed of via a suitable recycling centre Please contact your local authority or the retailer from where the product was purchased for information on available facilities Page 12 ...
Страница 15: ...acement of parts due to fair wear and tear 2 Abuse or misuse including but not solely limited to the failure to use this product for its normal purposes or in accordance with ERA s instructions on usage and maintenance 3 Failure of the product arising from incorrect installation or use not consistent with the instructions supplied and the cost of any removal or installation of products 4 Accidents...
Страница 16: ...Customer Helpline 0345 257 2500 www erahomesecurity com ERA Home Security Ltd Valiant Way Wolverhampton West Midlands WV9 5GB email support erahomesecurity com ...