ERA
, Straight Road, Willenhall, West Midlands. WV12 5RA
Tel: +44 1922 490049 Fax: +44 1922 494420 Email: [email protected]
www.erahomesecurity.com
D1
D2
E
F
Fitting the Staple
Close door and mark the position of the staple using the lock as a guide. Mark area
of wood to be removed from door frame and chisel out. Insert the 3 remaining
woodscrews provided to fix the staple, drilling the pilot holes is necessary.
G
Locate lock body over mounting plate and slide lock to engage locking pegs, ensuring
lock face (kitemarked edge) fits flush in recess. Replace the 2 retaining screws and
secure lock using the 2 wood screws provided.
F
Using lock as template, locate lock body over mounting plate. Mark area to be
removed from the door edge remove lock from mounting plate and chisel out so that
the lock face (kitemarked edge) sits flush. Mark the position of the 2 fixing holes.
Remove lock and drill positions marked, drilling pilot holes if necessary.
E
www.erahomesecurity.com
Remove mounting plate from lock body by unscrewing the 2 retaining screws.
Place the mounting plate over the connecting bar. Secure the mounting plate
to the cylinder pull using the two slotted connecting bolts through the mounting
plate top centre holes. Do not over tighten the bolts.
Note:
For doors less than 45mm thick, connecting bolts may need to be shortened
using a hacksaw.
Using the 4 wood screws provided, secure the mounting plate in positions A and C.
When fixing mount plate, if holes A are not suitable due to previous holes etc, plate
using positions B.
D
Maintenance -
Use a moist cloth only to clean all types of finish. Houshold abrasives
or solvents may affect the surface finish.
Deadlocking -
From inside, insert key into the handle and turn 360° and remove key.
The door cannot be opened from the inside. To unlock - reverse operation.
Operation -
Insert key from the outside and turn to open the door.
Additional Information