August 2012 – Ed.1.2
EQUITEL – E451 Technical manual
Page 19
Chapter 5
Configuration through web server
E451 has integrated a web server that allows accessing the configuration parameters from a remote site by
connecting through a Web browser.
The equipment is factory default configured with the following network access parameters:
IP:
192.168.1.1
Subnet mask:
255.255.255.0
Gateway:
0.0.0.0 (not used)
We will explain now the procedure to follow to gain access to the E451 web server:
•
Configure the computer IP address so as to be in the same subnet as E451, and make sure that there are
no other units in the network with the same IP.
•
Launch the explorer and type
http://192.168.1.1
in the address bar.
•
A page will ask for the password to access the web server. Initially, it is “
admin
”.
•
Once it is correctly introduced, you will gain access to the main page.
Figure 12.
Access page to E451 web server
Figure 13.
E451 web server homepage