background image

2

sink back

7, 8

20

21

1

Instructions

Installation: (5GF-W-F & 5GF-W)

1. Turn off water supply and drain lines.
Hand tighten no.

20

 fi rmly against no.

1

and remove no.

21

 from no.

1

.

2. Drill 7/8” hole in sheet metal. Insert no.

1

 

through hole and screw no.

21

 on back of no.

1

,

leaving no.

20

 free to turn. 

3. Apply tefl on tape or pipe joint compound to
threads of water supply line. Connect no.

1

 to

water supply line outlet, tightening as far as possible.

4. Tighten no.

20

 and no.

21

 so they are fl ush against surface of sink back.

5. Turn on water supply and check for leaks.

Flow Adjustment:
To adjust water flow, loosen no.7 with a wrench, then use 

screwdriver to turn no.8 to desired setting. Tighten no.7 when flow 

adjustment is complete.

1

7, 8

23

24

26

25

countertop

22

Installation: (5GF-8P & 5GF-8P-WS)

1. Turn off water supply and drain lines.

2. Unscrew  and remove no.

26

 and no.

25

 

from no.

23

. Position no.

24

 to cover threads 

of no.

23

.

3. Place no.

23

 through 7/8” hole in 

countertop. Replace no.

25

 and no.

26

 onto 

no.

23

 and tighten with a wrench at bottom 

side of countertop. 

4. Screw no.

1

 into no.

22

 and tighten fi rmly.

5. Apply tefl on tape or pipe joint compound 
to threads of no.

23

, connect to water supply 

line inlet.

6. Turn on water supply and check for leaks.

To adjust water flow, please refer to 

flow adjustment note for 5GF-W-F & 

5GF-W models.

Отзывы: