background image

www.prolight.co.uk

Vapour 1000

 

User Manual

4

On startup the LED display on the rear of the unit will show  

Up

 whilst the unit it heating up.

DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes  
to customising or creating a show. In this mode you will be able to control each individual trait of  
the fixture and each fixture independently. 
To access the DMX address mode, press the 

“MENU”

 button on the rear of the unit to show   

Addr

 on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

  

buttons to set the required DMX address. Press the 

“ENTER”

 button to confirm the setting.

 
 
 
 

Manual control mode:

To access the Manual control mode, press the 

“MENU”

 button on the rear of the unit to show  

out

  

on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to choose the 

desired haze amount between 

F001

 ~  

F100

. Press the 

“ENTER”

 button to confirm the setting.

To suspend the haze output press and hold the 

“ENTER”

 button to show  

read

. To resume the haze 

output press and hold the 

“ENTER”

 button again. The display will now show the last selected value.

To exit out of any of the above options, press the 

“MENU”

 button. 

Value: 001 - 100 (001 = no haze output, 100 = maximum haze output)

Master/slave mode:

To set the unit in master/slave, press the 

“MENU”

 button on the front of the unit to show  

SLnd

 on the 

LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to select between 

NASt

 ~  

SLAu

. Press the 

“ENTER”

 button to confirm the setting. 

To exit out of any of the above options, press the 

“MENU”

 button.  

Operating instructions

Operating instructions

MENU

DMX address setting

0 0 1

5 1 2

A d d r

Master/slave mode

N A s t

S L A v

S L n d

1 channel mode:

Channel

Value

Function

CH1

000-255

Haze output (0-100%)

Manual control mode

r e a d

F 0 0 1

F 1 0 0

o u t

Содержание Vapour 1000

Страница 1: ...Order code EQLED360 Vapour 1000 User Manual...

Страница 2: ...e come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the unit Do not open the equipmen...

Страница 3: ...d control panel 800W max heater Smoke output approx 30 000 cu ft per minute Warm up time approx 2 min Tank capacity 1 2 litres 4 push button menu with LED display 3 Pin XLR input output IEC power inpu...

Страница 4: ...the UP and DOWN buttons to choose the desired haze amount between F001 F100 Press the ENTER button to confirm the setting To suspend the haze output press and hold the ENTER button to show read To res...

Страница 5: ...a well ventilated area Use in an insufficiently ventilated room can lead to the condensation of the haze fluid The resulting slippery surface can cause accidents Keep a minimum distance of 1m around...

Страница 6: ...e carried out by authorized dealers Replacing the fuse Only replace the fuse with a fuse of same type and rating Before replacing the fuse disconnect from the mains see the following for procedure Ste...

Страница 7: ...ible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material re...

Страница 8: ...www prolight co uk Vapour 1000 User Manual 8...

Отзывы: