background image

www.prolight.co.uk

Verti Jet

 

User Manual

6

Remote:

Press the 

“MENU”

 button on the unit to show  

reNo

  

on the LED display. Now press the 

“ENTER”

 button and  

use the 

“UP”

 and 

“DOWN”

 buttons to select  

on

 or  

off

.  

Press the 

“ENTER”

 button to confirm the setting.

DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes  
to customising or creating a show. In this mode you will be able to control each individual trait of  
the fixture and each fixture independently. 
To access the DMX address mode, press the 

“MENU”

 button on the unit to show  

Addr

 on the  

LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to set the required 

DMX address. Press the 

“ENTER”

 button to confirm the setting.

Note: This unit is designed so the DMX control takes priority. When a DMX controller is connected the 
screen will display the current address code and wireless remote control function and the manual 
button function will both be disabled.

Operating instructions

Operating instructions

Output  

smoke

No  

smoke

Press ‘MENU’ key
Set DMX Address

‘ENTER’
confirm

‘ENTER’
confirm

‘ENTER’
DMX address

A d d r

0 0 1

5 0 6

Channel

Value

Function

CH1

000-009

Smoke off

010-255

Smoke output (full on)

CH2

000-255

Master dimmer (0-100%)

CH3

000-020

No function

021-127

Static colour

128-255

Auto (slow to fast)

CH4

000-009

Strobe off

010-255

Strobe (slow to fast)

CH5

000-255

Red dimmer (0-100%)

CH6

000-255

Green dimmer (0-100%)

CH7

000-255

Blue dimmer (0-100%)

Содержание EQLED356

Страница 1: ...Order code EQLED356 Verti Jet User Manual...

Страница 2: ...come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the unit Do not open the equipment...

Страница 3: ...rm up time approx 4 5 mins Tank capacity 2 5 litres DMX channels 7 Static colour colour change and auto modes Verti Jet 205mm 360mm 430mm 05 06 11 07 10 12 13 08 09 04 03 01 Smoke aperture 02 LED outp...

Страница 4: ...replacing the bracket and securing with the 2 spring loaded hand screws making sure they are firmly in position Installation Install the unit in a well ventilated area Use in an insufficiently ventil...

Страница 5: ...desired colour then press the ENTER button to confirm Press and hold the MANUAL button on or press the lock button on the remote for operation Please note Once the lock button on the remote has been...

Страница 6: ...the UP and DOWN buttons to set the required DMX address Press the ENTER button to confirm the setting Note This unit is designed so the DMX control takes priority When a DMX controller is connected t...

Страница 7: ...ease do the following Power off the unit and disconnect from mains power supply Refill the fluid tank Reconnect the mains power supply and power on the unit The unit can now be operated again after it...

Страница 8: ...carried out by authorised dealers Replacing the fuse Only replace the fuse with a fuse of same type and rating Before replacing the fuse disconnect from the mains see the following for procedure Step...

Страница 9: ...is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure...

Страница 10: ...in XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR...

Страница 11: ...ble harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material res...

Страница 12: ...www prolight co uk Verti Jet User Manual 12...

Отзывы: