DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes  
to customising or creating a show. In this mode you will be able to control each individual trait of  
the fixture and each fixture independently. 
To access the DMX address mode, press the 

“MENU”

 button and use the 

“UP”

 and 

“DOWN”

 buttons on 

the rear of the unit to show  

Addr

 on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 

and 

“DOWN”

 buttons to set the required DMX address. Press the 

“ENTER”

 button to confirm the setting.

 

To exit out of any of the above options, press the 

“MENU”

 button.

DMX channel mode:

To access the DMX channel mode, press the 

“MENU”

 button and use the 

“UP”

 and 

“DOWN”

 buttons on 

the rear of the unit to show  

Chnd

 on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 

and 

“DOWN”

 buttons to choose one of the 4 or 26 DMX channel modes. Press the 

“ENTER”

  

button to confirm the setting. To exit out of any of the above options, press the 

“MENU”

 button.

Operating instructions

4 Channel

26 Channel Function

Value

1

1

Master dimmer (0-100%)

000-255

2

2

No function

000-007

Strobe (slow-fast)

008-255  

3

Colour Chase

No function

000-007

Chase 01

008-022

Chase 02

023-037

Chase 03

038-052

Chase 04

053-067

Chase 05

068-082

Chase 06

083-097

Chase 07

098-112

Chase 08

113-127

Chase 09

128-142

Chase 10

143-157

Chase 11

158-172

Chase 12

173-187

Chase 13

188-202

Chase 14

203-217

Chase 15

218-232

Chase 16

233-247

All Chase

248-255

6

Chase Auto Speed (slow-fast)

000-127

Chase Sound Sensitivity (slow-fast)

128-255

3

Red 1 dimmer (0-100%)

000-255

4

Green 1 dimmer (0-100%)

000-255

5

Blue 1 dimmer (0-100%)

000-255

6

White 1 dimmer (0-100%)

000-255

7

Red 2 dimmer (0-100%)

000-255

Содержание EQLED203

Страница 1: ...Order code EQLED203 Super Boogie User Manual...

Страница 2: ...s life Only use the equipment indoors Do not sit the equipment on a flat surface as this can block the air intake to cool the LED Do not expose to flammable sources liquids or gases Always disconnect...

Страница 3: ...and built in show modes 24 x 3W LEDs R 6 G 6 B 6 A 6 Beam angle 78 DMX channels 4 6 or 26 selectable Auto sound active and master slave modes 0 100 dimming and variable strobe IR remote control includ...

Страница 4: ...UT DMX OUTPUT SAFETY ETE www prolight co uk MENU ENTER MIC DOWN UP POWER OUTPUT 100 240V 50 60Hz POWER INPUT 100 240V 50 60Hz FUSE F3A 250V POWER CONSUMPTION 72W SAFETY ETE www prolight co uk MENU ENT...

Страница 5: ...d r DMX address setting N A S t S L 1 S L 2 S L n d Master slave mode t e s t Auto Test 5 o 0 5 o 1 6 5 e 9 9 5 e 0 S o U n Sound active v e r Firmware Version v 1 0 o N o F F L E d Display blackout D...

Страница 6: ...f the unit to show Chnd on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 4 or 26 DMX channel modes Press the ENTER button to confirm the setting To ex...

Страница 7: ...00 000 255 13 Blue 3 dimmer 0 100 000 255 14 White 3 dimmer 0 100 000 255 15 Red 4 dimmer 0 100 000 255 16 Green 4 dimmer 0 100 000 255 17 Blue 4 dimmer 0 100 000 255 18 White 4 dimmer 0 100 000 255 1...

Страница 8: ...the LED display Now press the ENTER button and use the UP and DOWN buttons to choose between So 0 to So16 Press the ENTER button and use the UP and DOWN buttons to select the sound sensitivity between...

Страница 9: ...ENTER button The unit will now display the fixtures software version e g u10 To exit out of any of the above options press the MENU button IR remote functions Button functions 01 Sets the unit into bl...

Страница 10: ...ll makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmis...

Страница 11: ...e adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Si...

Страница 12: ...UP POWER OUTPUT 100 240V 50 60Hz POWER INPUT 100 240V 50 60Hz FUSE F3A 250V POWER CONSUMPTION 72W DMX INPUT DMX OUTPUT SAFETY ETE www prolight co uk MENU ENTER MIC DOWN UP POWER OUTPUT 100 240V 50 60...

Отзывы: