background image

EVR – Vacuum Series - 

Precision Back Pressure Regulator

 

 

EVR-Series Installation and Operating Instructions 

1/12/12

 

 

These instructions apply to all Equilibar model EVR regulators 
with the 20 turn set point adjuster installed by the factory.   The 
EVR consists of a dome-loaded back pressure regulator (on 
bottom) with a set-point regulator on top.  The body is stamped 
with an ”I” for inlet which should be connected to the process 
to be controlled.  The “O” (outlet) is to be connected to lines 
from the vacuum source (or pump).

  

A typical installation will have a schematic similar to that 
shown at the right.   (Note: The line to the 20 turn adjustment 
comes integrated)  You may wish to mount the 20 turn 
adjustment in another location.   Instrument grade plastic 
tubing can be used to pipe the source vacuum for this change.  

Installation Notes 

 

Use a strainer to protect the inlet of the Equilibar if 
debris is expected in your vacuum process. 

 

Inlet and Outlet ports are stamped “I” and “O” as 
shown. 

 

Connect your vacuum pump or supply to the “O” 
port. 

 

Connect the “I” port to your process needing 
pressure control. 

Take precautions to prevent injury to personnel in the event 
of a diaphragm failure or external leak.  Sensitive fluid 
controls can experience external or internal leaks. 

Maintenance Notes 

 

Maintain strainer or filter upstream of device 

 

Annual inspection of diaphragm integrity is recommended, especially for applications where there 
is strong or regular pulsing (i.e. reciprocating pump, etc.).   

Trouble Shooting: 

Problem 

Possible solutions 

 

Cannot achieved desired vacuum levels 

 

Adjust 20 turn knob 

 

Check for inlet and outlet reversed; change installation if 
necessary 

 

Look for obstructions in vacuum supply lines 

 

Vacuum pumps may need maintenance 

 

No control over vacuum level 

 

Diaphragm may ruptured; check and replace if necessary 

 

Debris in regulator;  Disassemble and clean unit 

 

20 turn adjuster may have been damaged; check and replace 
if necessary 

 

Hissing noise comes from regulator 

 

Leaks in control line to 20 turn adjuster; replace tubing 

 

Inlet 

Exhaust 

Отзывы: