RELEASE RIGHT SIDE PANEL
1.2
CHECK COMPLETE RESINS
REGENERATION PROCESS
Observe “AIR BREAK” filling of
deposits
Does it fill ?
CAUSE
NO
T R EATMENT
- After repair wash dishes
with citric acid, vinegar or
machine-cleaner.
Do the deposits empty ?
Correct regeneration cycle
-Carry out various
regenerations.
-Measure water hardness in
tub interior.
Higher than
12 HF or 7 DM ?
-Incorrect closing of salt
deposit cap.
-E.V. regeneration blocked in
open position
Yes
YES
NO
Yes
Problem resolved. Wash dishes
with citric acid “vinegar or
machine-cleaner”
CAUSE
Decalcifier without resins
Decalcifier saturated
NO
Connect the E.V. directly
Do the deposits empty ?
NO
YES
Current does not reach
the E.V.
T R EATMENT
-
- Review installation of the program
selector to the EV.
- Clean dishes and machine with
citric acid “vinegar or machine-
cleaner”.
CAUSE
- Defective or seized up E.V.
-internal conduits of the decalcifier
blocked “careful with the salt used if it is
excessively fine.
F
IMPORTANT : It has been found that the majority of resin-saturated decalcifiers can be repaired by appropriate regenerations.
T R EATMENT
- Repair and clean dishes with citric
acid “vinegar or machine-cleaner”.
Carry out a regeneration process
16.