![EqualLogic PS3000 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/equallogic/ps3000-series/ps3000-series_quick-start-manual_2420593014.webp)
PS Series 3000 QuickStart
Step 1. Set Up the Array Hardware
6
B. Mount Array in a Stable Rack
A PS Series array must be mounted in a two-pole or four-pole 19” rack.
Instructions for rack assembly and mounting an array are included with the
two-pole assembly kit and the four-pole assembly kit in the array shipping box.
When mounting an array in a rack, you must meet the following recommendations
and requirements:
•
Be sure there is sufficient space for air flow in front of and behind the array.
•
It is recommended that you attach the rack to the floor for added stability.
•
Be sure to support the array until it is completely mounted in the rack.
•
The location of the array must be properly vented and must meet the
environmental, power, and physical requirements described in the
following table.
PS Series Storage Array Requirements
Component
Requirement
Weight of fully-loaded array
80 pounds or 36.36 kilograms
Operating temperature
41 to 104 degrees F / 5 to 40 degrees C
Storage temperature
-22 to 140 degrees F / -30 to 60 degrees C
Maximum altitude
10,000 feet
Operational relative humidity
8 to 90% non-condensing
Thermal output of fully-loaded array
2200 BTU/hour, 660 watts
Shock
30 G for 2 ms
Vibration
.1 G @ 10 to 100 hertz
Input voltage
90 to 264 VAC (auto-sensing)
Input current
5.5 amperes (maximum, single power supply)
@ 120 volts
Input frequency
50 to 60 hertz
Input power
660 VA
Power supplies
Dual, 450 watts DC output
Height/Width/Depth
5.25” x 17 5/8” x 22.5”
13.33 cm x 44.77 cm x 56.25 cm