Trouble Shooting Guide
Temperature Rise by Model Number
H&S 5
H&S 11
Hours
Hours
Hours
Hours
Model
Gallons
20° Rise
40° Rise
20° Rise
40° Rise
T2S
800
6.67
14.29
3.56
7.14
T2M
865
7.21
15.45
3.84
7.72
T2L
1050
8.75
18.75
4.67
9.68
S1
590
4.92
10.54
2.62
5.67
S2
690
5.75
12.32
3.07
6.16
MX
705
5.88
12.59
3.13
6.29
M1
750
6.25
13.39
3.33
6.70
M2
795
6.63
14.20
3.53
7.10
MINI
490
4.08
8.75
2.18
4.38
R1
715
5.96
12.77
3.18
6.38
R2
850
7.08
15.18
3.78
7.59
EZ1
350
2.92
6.25
1.56
3.13
EZ2
465
3.88
8.30
2.08
4.15
Nothing Operates:
Main Breaker
Set to on position
Sub-panel circuit breaker
Set to on position
GFIC tripped
Set to on position
Components not plugged in
Plug in all components
Time Clock has turned system off
Adjust time clock
Overheat Protection Switch tripped
Reset High Limit Switch and monitor closely. If condi-
tion repeats, contact Service Center.
No Pump Operation:
Timer not programmed
Program timer for on/off operation
Overheat Protection switch tripped
Reset High Limit Switch and monitor closely. If condi-
tion repeats, contact Service Center.
Mode Switch set in Mode 2
Turn up thermostat
Air Switch activated
Press air switch again
Pump not plugged in
Plug in pump