background image

CAUTION! 

Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

CAUTION! 

This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains 

no user replaceable parts. Only authorized service personnel may perform repairs. 

CAUTION!

 Do not attach a power strip or surge suppressor with >1,5m wire to the UPS 

CAUTION! 

Do not stick fingers into sockets. 

 
 

 
Please follow the instructions to correctly position your UPS: 

1.  The UPS must be placed on a horizontal surface. 
2.  This UPS is projected for indoor use. 
3.  The UPS must not be exposed to direct sunlight or any heat source. 
4.  The air temperature must be between 0°C and 40°C (25°C is the ideal temperature). 
5.  Ambient humidity must be less than 90%. 
6.  The UPS must not be placed on dusty environments. 
7.  The UPS must be placed at least 15 cm. far from walls to ensure enough ventilation. 
8.  Do not obstruct or pour any liquid on ventilation holes. 
9.  Do not cover the UPS with any object. 

10.  Keep away liquids, flammable gases or corrosive substances. 

 

INSTALLING YOUR UPS SYSTEM 

 

UNPACKING 

 

The box should contain the following: UPS unit x1, USB cable x1, IEC cable x1.  

 

 

HARDWARE INSTALLATION GUIDE 

 

1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is 

recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss may occur during 
shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge 
in both the ON and OFF position. 

2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage 

device (Zip drive, Jazz drive, Tape drive, etc.) into the battery power supplied outlets. DO NOT plug a laser printer, 
copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets. 
The power demands of these devices will overload and possibly damage the unit. 

3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected 

by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, 
refrigerator, copier, etc). Avoid using extension cords. 

4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep". 
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the 

UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make 
sure the circuit breaker is depressed and then turn the UPS on. 

6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
7. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery 

every three months to ensure battery life. 

 

 

Front panel 

1. Power Switch 

Press the switch for 2 seconds to turn the UPS ON or OFF. 

Sound disable: 

the audible alarm can be turned OFF or ON by quickly 

pressing the power switch twice. The default setting is for the Alarm On. 

2. Led Indicator 

This LED is illuminated when the UPS is working.

 

 

3. LCD Display

 

 

The LCD will display the UPS status including input voltage, output 

voltage, percentage of load and battery…etc. 

 

Rear panel 

1. USB COMM. Port 

This port allows connection to the USB port on the computer, so to get 

access to remote monitoring and shutdown operations through the UPS 

management software. 

2. Input Circuit Breaker

 

 

The circuit breaker provides optimal overload protection. 

3. Input power cord  

Connect to utility power.

 

 

4. Battery Backup & Surge Protected Outlets 

The UPS provides outlets for connected equipment to insure temporary 

uninterrupted operation during a power failure and against surges and 

spikes. 

 

 

 

 

 

 

LCD Display layout 
 

 

 

 

 

 

Indicators definition 

 

 

Line mode 

 

Battery mode 

 

Fault/Alarm 

 

Sound disabled 

 

Battery mode

 - Battery capacity 

Line mode 

- Battery charging (cycle lighting) 

- Battery full charghed (lighting) 

 

Load capacity 

 

AC Input voltage 

 

Output voltage 

 

POSITIONING 

INSTALLING YOUR UPS SYSTEM 

DEFINITIONS FOR ILLUMINATED LED INDICATORS 

BASIC FUNCTIONALITIES 