Epson WF-7620/7610/7110 Series
Revision B
Disassembly/Reassembly
Routing FFCs/cables
48
Confidential
Inside the USB Cover (ADF Unit/Cables related to Scanner Unit (WF-7620/WF-7610 Series)
For the correspondence between the cables, FFCs and the connectors on the Main Board, see
.
When routing the Scanner motor cable (CN32), ADF document sensor cable (CN72), ADF encoder sensor cable (CN73), Paper Support Encoder Sensor
cable (CN76), follow the procedure below.
•
Insert the cables from the hole A on the Housing Upper and route them through the hook B, rib A (x2), and rib B (x3) on the Frame Base 1st, then route
them inside the rib C and connect them to their connectors on the Main Board.
•
Set the ferrite core A of the Scanner Motor cable as shown above.
Route the ADF motor cable (CN33), ADF PE sensor cable (CN71), ADF Plunger cable (CN77), and Scanner Open Sensor cable (CN74) as shown below.
•
Insert the cables from the hole A on the Housing Upper and route them through the hook A and the slit on the Frame Base 1st, then connect them to their
connectors on the Main Board.
•
Set the ferrite core B of the ADF Motor cable as shown above.
Insert the Grounding Wires (x3) from the hole A on the Housing Upper, and secure them at the position shown above with the screw.
Route the Scanner FFC as follows.
1. Insert it into the hole B of the Housing Upper, and route under the rib D of the Housing Upper.
1. Thread the Scanner FFC through the ferrite core C, and secure the ferrite core C to the position shown above with double-sided tape.
2. Secure the Scanner FFC on the position shown above with double-side tape, and then connect the FFC to the connector (CN70) on the Main Board.
Put the excess portion of the cables after routing into the space between the Housing Upper and Main Board.
Hole A
Hole B
Housing Upper
Upper: Before ADF/Scanner Unit is installed
Frame Base 1st
Space between Housing
Upper and Main Board
Ferrite core A
Slit
Ferrite core B
Hook A
Rib A
Double-sided tape
C.B.S-TITE SCREW 3x6 F/ZN-3C (6±1 kgf
·
cm)
Rib B
メ イ ン基板
Scanner FFC
Grounding
Wire
Ferrite core C
Rib D
Hook B
Rib C
Rib D
•ADF motor cable
•ADF PE sensor cable
•ADF plunger cable
•Scanner Open Sensor cable
•Scanner Motor cable
•ADF document sensor cable
•ADF encoder sensor cable
•Paper Support Encoder Sensor cable
Housing Front Assy (WF-7620/WF-7610 Series)
Route the cables and FFC to the Housing Front Assy as follows.
Panel Grounding Wire
Wrap it around the point shown above three times and route it along the shape of Housing Front Assy, then secure it on the Main Board Unit with the screw.
Cover Open Sensor cable
Route it along the shape of Housing Front Assy, then connect it to the connector (CN53) on the Main Board Unit.
Panel FFC
Route it along the rear of the Housing Front Assy and pull it out from the hole, then secure the FFC and the ferrite core to the position shown above with
double-sided tape.
Rear
Align with standard line
and secure with tape.
Hole
Panel FFC
C.B.S-TITE SCREW 3x6 F/ZN-3C (8±1
kgf
·
cm)
Cover Open Sensor cable
Double-sided tape
Standard line
Housing Front Assy
Panel Grounding Wire
Panel FFC
Ferrite core
Wrap three times.
Main Board Unit
Hole
Panel Unit's bottom(WF-7620/WF-7610 Series)
Route the cables and FFCs on the bottom of the Panel Unit as follows.
Panel Grounding Wire
Secure on the Panel Board with the screw.
Speaker Cable
Connect to the Relay cable.
Panel FFC
Set the ferrite cores (x2) in the positions shown above and secure the FFC
with double-sided tape, then connect it to the connector (CN20) on the
Panel Board.
Panel Unit's bottom
Double-sided tape
Speaker cable
Relay cable
Panel Board
Panel Grounding Wire
Panel FFC
Ferrite core
C.B.P-TITE SCREW 3x10 F/ZN-3C (6±1
kgf
·
cm)
FAX Unit (WF-7620/WF-7610 Series)
Secure the ferrite core to the position shown above with double-sided tape.
Thread the FAX FFC through the ferrite core and route it according to its
folds and connect it to the connector (CN5) on the Main Board, then
secure it to the position shown above with double-sided tape (x2).
Main Board
Ferrite core
FAX FFC
FAX Unit
Double-sided tape
Содержание WF-7110 Series
Страница 8: ...5 2 Protection for Transportation 86 5 2 1 Securing the CR Unit 86 ...
Страница 9: ...Confidential CHAPTER 1 TROUBLESHOOTING ...
Страница 23: ...Confidential CHAPTER 2 DISASSEMBLY REASSEMBLY ...
Страница 52: ...Confidential CHAPTER 3 ADJUSTMENT ...
Страница 75: ...Confidential CHAPTER 4 MAINTENANCE ...
Страница 84: ...Confidential CHAPTER 5 APPENDIX ...