![Epson TM-T81 Скачать руководство пользователя страница 135](http://html.mh-extra.com/html/epson/tm-t81/tm-t81_technical-and-specifications-manual_107646135.webp)
Confidential
EPSON
TITLE
SHEET
REVISION
NO
SHEET
NEXT
A
App.12 App.11
TM-T81
Specification
(STANDARD)
APPENDIX G: NOTES ON UPDATING THE MAINTENANCE COUNTER
AND TURNING THE PRINTER’S POWER OFF
G.1 About updating the maintenance counter
•
This printer has a maintenance counter function, as described in the command description for
GS
g 0
and
GS g 2
.
•
The values of the maintenance counter are automatically stored in the NV memory every 2
minutes (or 4 minutes maximum) when the printer is operating, except in the power save mode.
•
However, if the power off is performed as described in Section G.2, the printer stores the latest
values of the maintenance counter and executes the power off control, regardless of the updating
interval described above.
•
If the printer is not sending/receiving data or is not operating for two seconds while the power is
turned on, the printer enters the power-saving mode and all of the values of the maintenance
counter including the printer operation time stop counting.
G.2 Power off procedure by the host
The following is an example of the printer power off process when the printer is turned off using the
DLE DC4
(
fn
= 2) command.
1) The host transmits the following continuous procedure before the system is turned off:
c
Executes
GS ( D
p
L
p
H
m a b
(
p
L
=3,
p
H
=0,
m
=20,
a
=2,
b
=1)
d
Executes
GS r
n
(
n
=1)
2) The host waits for the paper sensor status sent from the printer in response to the
GS r
n
command.
3) The host transmits
DLE DC4
fn a b
(
fn
=2,
a
=1,
b
=8).
4) The host waits for the power off status.
•
The values of the maintenance counter are stored and the power-off sequence is performed
within 20 seconds after the host transmits
DLE DC4
fn a b
; then the power off status is
transmitted.
•
For the USB interface model, the printer is required to be ready for receiving data from the
host.
•
For the serial interface model, the printer status is transmitted regardless of the condition of
the host.
•
For the parallel interface model, after the host transmits
DLE DC4
fn a b
, the printer is
required to be ready for receiving data from the host.
•
If the power off status in not confirmed, wait for 20 seconds at least after transmitting
DLE
DE4
fn a b
.
NOTE: The printer executes the software sequence, but the power is not cut.
5) Please turn the host power off.
NOTE: Do not execute a reset to the printer until the printer power is turned off after transmitting
DLD DC4 (fn = 2).