EPSON Stylus PHOTO 2100/2200
Revision A
TROUBLESHOOTING
Troubleshooting
98
At power-on
At power-on, the ASF unit does
not operate at all.
ASF motor
1. Check that the ASF motor connector cable is connected to CN8
on the Main board correctly.
2. Using a tester, check that the resistance of the ASF motor is
7.0
Ω ±
10%. (Across Pins 1 and 3 and across Pins 2 and 4,
respectively)
3. Check the ASF motor connector cable for damage.
1. Connect the ASF motor connector cable to
CN8 on the Main board correctly.
2. If the resistance value is abnormal, change the
ASF motor for a new one.
3. Change the ASF motor for a new one.
At power-on, the ASF unit does
not operate at all.
Extension spring
0.618
1. Check that the Extension spring 0.618 is mounted between the
DE lock lever and DE unit.
2. Check the Extension spring 0.618 for damage.
1. Install the Extension spring 0.618 between the
DE lock lever and DE unit.
2. Change the Extension spring 0.618 for a new
one.
Table 3-17. Phenomenon-Based Fatal Error Check Points
Occurrence Timing
Phenomenon Detail
Faulty Part/Part
Name
Check Point
Remedy
ASF motor
Left rear side
Extension spring 0.618
DE lock lever
Содержание StylusRIP Professional (Stylus Photo 2200
Страница 1: ...EPSONStylusPHOTO2100 2200 Color Inkjet Printer SEIJ01 016 SERVICE MANUAL ...
Страница 5: ...Revision Status Revision Issued Date Description A May 24 2002 First Release ...
Страница 8: ...C H A P T E R 1 PRODUCTIONDESCRIPTION ...
Страница 39: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 69: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 114: ...EPSON Stylus PHOTO 2100 2200 Revision A TROUBLESHOOTING EEPROM Data Analysis 114 3 4 EEPROM Data Analysis T B D ...
Страница 115: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 187: ...C H A P T E R 5 ADJUSTMENT ...
Страница 214: ...C H A P T E R 6 MAINTENANCE ...
Страница 226: ...C H A P T E R 7 APPENDIX ...
Страница 254: ......
Страница 255: ......
Страница 256: ......
Страница 257: ......
Страница 258: ......