EPSON Stylus Pro 7400/7800/9400/9800
Revision B
Troubleshooting
Troubleshooting based on Panel Messages
189
Remedy
1. Check the life count of the CR Motor in the
Press the [Menu] button
→
PRINTER STATUS menu -
SERVICE LIFE
→
See Section 1.4.4.30 on page 84.
•
When the life is still remaining
•
When the life has expired or close to the end-of-life
2. As the lifespan of the CR Motor means the lifespan of the printer, the whole
printer mechanism checks and corresponding maintenance works must be
carried out. Especially, the following items should be carefully checked or
performed.
•
Check the Head FFC for any damage such as break, scratch, etc.
•
Check the CR Timing Belt and the PF Timing Belt for any damage.
•
Check if abnormal sounds are produced from the sliding surfaces of the
Guide Rail and the bearings of the Carriage Unit (wear of the bearings).
•
Check if the paper dust or any other dust accumulates on the paper path.
If it does, clean it as indicated in
“6.1.2 Required Maintenance Items”
•
Refer to
and lubricate the specified points if
necessary.
SERVICE CALL 00010000
Description
PF Encoder check error
Explanation
The printer causes this error and stops operation if it cannot detect the encoder
pulse signals at intervals of the specified time during the power-on initialization
operation or while the PF Motor is driving.
Possible Causes
The PF Encoder connector is disconnected.
The PF Motor connector is disconnected.
The Encoder harness on the PF side is broken.
The wiring of the A and B phases are wrong (opposite)
The wiring of the motor is wrong (opposite)
The PF Motor shorted out.
The PF Motor is energized continuously and kept rotating abnormally.
The fuse for the motor driver is blown. (on the Main Board)
The Main Board is damaged. (+42V/+24V remote control is broken)
The Power Supply Board is damaged (42V is OFF)
Check Point
1. Make sure that the PF Encoder and the PF loop scale are free of dust or
foreign materials.
2. Perform the Encoder check by the
“1.4.6.1 Self Testing Menu (SELF
3. Make sure that the PF Timing Belt is normal and its tension is appropriate.
4. Make sure that the Grid Roller rotates smoothly without any abnormal load.
5. Make sure that the PF Motor is not shorted out.
If it does, replace the C594 Main Board together with the PF Motor.
6. Make sure that the harnesses are connected correctly and not broken.
Remedy
1. Clean dirt or paper dust on the Loop Scale and check if it is damaged.
2. Reconnect the PF Encoder connector or the PF Motor connector securely.
3. Execute the
PF Timing Belt Tension Adjustment
.
4.
5.
6.
C H E C K
P O I N T
Whenever the CR Motor Assy. is replaced, the corresponding
adjustment (including resetting the counter) must be carried
out.
Do not reset the CR TOTAL counter (CR Motor cumulative
life counter).
Содержание Stylus Pro 7400
Страница 1: ...EPSONStylusPro7400 7800 9400 9800 Large Format Color Inkjet Printer SERVICE MANUAL SEIJ05002 ...
Страница 10: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 147: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 170: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 207: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Страница 292: ...C H A P T E R 5 ADJUSTMENT ...
Страница 373: ...C H A P T E R 6 MAINTENANCE ...
Страница 380: ...C H A P T E R 7 APPENDIX ...
Страница 385: ...Model PX 7500 7500S 9500 9500S Board C594 Main Sheet 1 of 4 Revison G ...
Страница 386: ...Model PX 7500 7500S 9500 9500S Board C594 Main Sheet 2 of 4 Revison F ...
Страница 387: ...Model PX 7500 7500S 9500 9500S Board C594 Main Sheet 3 of 4 Revison F ...
Страница 388: ...Model PX 7500 7500S 9500 9500S Board C594 Main Sheet 4 of 4 Revison E ...
Страница 389: ...Model PX 7500 7500S 9500 9500S Board C594 SUB Sheet 1 Revison C ...
Страница 390: ...Model PX 7500 7500S 9500 9500S Board C594 SUB B Sheet 1 Revison E ...
Страница 391: ...Model PX 7500 7500S 9500 9500S Board C594 SUB C Sheet 1 Revison D ...
Страница 392: ...Model PX 7500 7500S 9500 9500S Board C594 PNL Sheet 1 Revison D ...
Страница 395: ...PX 7500 7500S E PS ON S TYLUS PR O 7400 7800 No 02 R ev 01 C594 CAS E 021 152 150 152 152 152 151 ...
Страница 396: ...PX 7500 7500S E PS ON S TYLUS PR O 7400 7800 No 03 R ev 01 C594 E LE C 011 202 201 200 ...
Страница 397: ...PX 7500 7500S E PS ON S TYLUS PR O 7400 7800 No 04 R ev 01 C594 E LE C 021 203 204 ...
Страница 398: ...PX 7500 7500S E PS ON S TYLUS PR O 7400 7800 No 05 R ev 01 C594 POWE 011 300 301 302 ...
Страница 403: ...PX 7500 7500S E PS ON S TYLUS PR O 7400 7800 No 10 R ev 01 C594 ME CH 051 700 701 X15 700 ...
Страница 407: ...900 901 906 901 905 903 903 904 PX 7500 7500S E PS ON S TYLUS PR O 7400 7800 No 14 R ev 01 C594 ME CH 091 902 ...
Страница 409: ...PX 9500 9500S E PS ON S TYLUS PR O 9400 9800 No 02 R ev 01 C595 CAS E 021 150 151 152 152 152 152 ...
Страница 410: ...R ev 01 C595 E LE C 011 200 201 202 PX 9500 9500S E PS ON S TYLUS PR O 9400 9800 No 03 ...
Страница 411: ...PX 9500 9500S E PS ON S TYLUS PR O 9400 9800 No 04 R ev 01 C595 E LE C 021 204 203 ...
Страница 412: ...PX 9500 9500S E PS ON S TYLUS PR O 9400 9800 No 05 R ev 01 C595 POWE 011 300 302 301 ...
Страница 417: ...PX 9500 9500S E PS ON S TYLUS PR O 9400 9800 No 10 R ev 01 C594 ME CH 051 701 X15 700 700 ...
Страница 421: ...900 901 906 901 905 903 903 904 PX 9500 9500S E PS ON S TYLUS PR O 9400 9800 No 14 R ev 01 C595 ME CH 091 902 ...