background image

In pursuit of “Saving” Technology, Epson electronic devices.

Our lineup of semiconductors, liquid crystal displays and quartz devices

assists in creating the products of our customers’ dreams.

Epson IS energy savings.

Содержание S5U1C88000H5

Страница 1: ...MF1272 03 CMOS 8 BIT SINGLE CHIP MICROCOMPUTER S1C88 Family In Circuit Emulator S5U1C88000H5 Manual ...

Страница 2: ...and there is no representation or warranty that anything made in accordance with this material will be free from any patent or copyright infringement of a third party This material or portions thereof may contain technology or the subject relating to strategic products under the control of the Foreign Exchange and Foreign Trade Law of Japan and may require an export license from the Ministry of In...

Страница 3: ... written in the manuals Previous No E0C88104 E0C88112 E0C88308 E0C88316 E0C88317 E0C88348 E0C88P348 E0C88349 New No S1C88104 S1C88112 S1C88308 S1C88316 S1C88317 S1C88348 S1C8P348 S1C88349 Previous No E0C88365 E0C88F360 E0C88408 E0C88409 E0C88816 E0C88832 E0C88862 E0C88F816 New No S1C88365 S1C8F360 S1C88408 S1C88409 S1C88816 S1C88832 S1C88862 S1C8F816 Comparison table between new and previous numbe...

Страница 4: ......

Страница 5: ...nvironment 1 CHAPTER 2 S5U1C88000H5 PACKAGE __________________________________ 2 2 1 Components 2 2 2 Component Specifications 2 CHAPTER 3 IN CIRCUIT EMULATOR S5U1C88000H5 ______________________ 3 3 1 Outline 3 3 2 Operating Environmental Conditions 3 3 3 Specifications of Operation Panel 4 CHAPTER 4 SETTING UP EQUIPMENT ____________________________________ 5 CHAPTER 5 INSTALLING SOFTWARE ________...

Страница 6: ......

Страница 7: ... computer ICE88UR E0C88 Family In Circuit Emulator Fig 1 1 1 S5U1C88000H5 external view 1 2 Operating Environment To construct an S5U1C88000H5 system the following equipment is necessary in addition to this package Personal computer IBM PC AT or compatible model with Windows 98 installed 80486DX2 66 MHz CPU or higher and 24MB RAM are recommended A USB port is required in the personal computer A ha...

Страница 8: ...mponent Specifications Table 2 2 1 shows the component specifications in the S5U1C88000H5 package Table 2 2 1 S5U1C88000H5 component specifications Components S5U1C88000H5 main unit USB I F cable AC adapter AC cable Accessories Package Remarks Rubber feet included Peripheral Circuit board is sold separately Rubber feet excluded Outside 5 V Inside 0 V One each for English and Japanese Items Dimensi...

Страница 9: ... 512KB emulation memory This part can be allocated to a 512KB area within address 010000H to address FFFFFFH To allocate the emulation memory to a 512KB area to be used specify the address in a parameter file that is read at the S5U1C88000H5 system start up Thus the emulation memory can be used as an external memory that is generally prepared on the target board if the capacity of the external mem...

Страница 10: ...arget system In case the above terminal is monitored with such an oscilloscope the GND line of the oscilloscope is connected to this terminal This is also used as a GND in case the signals are input to the above terminals This green LED lights upon power on of S5U1C880000H5 This red LED lights when the target program is in running status This yellow LED lights when the S1C88 CPU stops executing th...

Страница 11: ...0H5 The target board is connected to the Peripheral Circuit Board Refer to the Peripheral Circuit Board manual of each model for how to install the Peripheral Circuit and target boards 2 Connecting the USB interface cable Connect the S5U1C88000H5 to the personal computer using the USB interface cable supplied in this package 3 Connecting the AC adapter Be sure to use the AC adapter supplied in thi...

Страница 12: ...eration i e click but key operation is also available When using the keyboard enter the underlined letter on the buttons 1 Start Windows 98 If the OS is already active close active programs 2 Insert the supplied disk into the drive 3 Double click Setup exe Welcome 4 Click on the Next button to proceed Choose Destination Location A dialog box for specifying the folder in which to install the tools ...

Страница 13: ...ll start installing the tools Setup Complete 7 Click Finish to terminate the installer Program menu The folder of tools is registered to the program menu by the installer To end installation All dialog boxes that appear during installation have a Cancel button To prematurely terminate installation click Cancel in the dialog box when it is displayed To uninstall To uninstall the installed tools use...

Страница 14: ...e a malfunction in the S5U1C88000H5 The S5U1C88000H5 debugger checks the S5U1C88000H5 hardware and files required The check result is displayed in the Command window If any error message appears and the debugger does not start up normally terminate the debugger choose Exit command from the File menu then check the follow ing points Is the Peripheral Circuit Board installed in the S5U1C88000H5 prop...

Страница 15: ... program and sets it as the default parameter file so that the debugger will read the file at start up To set the debugger to read an actual parameter file used for development it is necessary to rewrite this Path specification so that the necessary parameter file will be read in Example Path DEFAULT PAR Path C E0C88 DEV88316 88316 PAR When specifying a parameter file existing in the same folder a...

Страница 16: ...uts off the circuit breaker of the S5U1C88000H5 4 Difference between the emulation memory and the RAM in the actual IC Both the S5U1C88000H5 emulation memory and the RAM in the actual IC are undefined at power on The set values are not same therefore be sure to initialize the memory with the program 5 Difference between memory operations by the debugging commands and memory access by programs Memo...

Страница 17: ...ter Ctrl R Modifying registers R Search Data Shift F3 Data search DS Symbol F3 Symbol search SYS Trace Ctrl F3 Trace memory search TS View Source Source level Ctrl 1 C source display SET Source ASM Mix Ctrl 2 C source disassembly display SET Source ASM Ctrl 3 Disassembly display SET Dump Ctrl D Memory dump D Trace Ctrl T Trace data dump TD Coverage Coverage display CV List Alt F3 Specifying progra...

Страница 18: ...2 Variable display VAR History Ctrl H Command history Window Cascade Arrangement of windows Tile Horizon Arrangement of windows Tile Vertical Arrangement of windows Arrange Icons Arrangement of icons 1 Source Alt 1 Opening Source window OW 2 Dump Alt 2 Opening Dump window OW 3 Register Alt 3 Opening Register window OW 4 Parallel dump Alt 4 Opening Parallel dump window OW 5 Local Alt 5 Opening Loca...

Страница 19: ...el Vallès SPAIN Phone 34 93 544 2490 Fax 34 93 544 2491 ASIA EPSON CHINA CO LTD 28F Beijing Silver Tower 2 North RD DongSanHuan ChaoYang District Beijing CHINA Phone 64106655 Fax 64107319 SHANGHAI BRANCH 4F Bldg 27 No 69 Gui Jing Road Caohejing Shanghai CHINA Phone 21 6485 5552 Fax 21 6485 0775 EPSON HONG KONG LTD 20 F Harbour Centre 25 Harbour Road Wanchai Hong Kong Phone 852 2585 4600 Fax 852 28...

Страница 20: ...ursuit of Saving Technology Epson electronic devices Our lineup of semiconductors liquid crystal displays and quartz devices assists in creating the products of our customers dreams Epson IS energy savings ...

Страница 21: ... www epson co jp device S1C88 Family In Circuit Emulator S5U1C88000H5 Manual EPSON Electronic Devices Website ELECTRONIC DEVICES MARKETING DIVISION First issue February 2000 Printed March 2001 in Japan A M ...

Отзывы: