9. Pressure Sensor (Serial Interface)
22
EPSON
S5U1C6F632T1/T2 (SVT6F632) Hardware Manual
9. Pressure Sensor (Serial Interface)
The SVT6F632 uses the S1C6F632’s built-in serial interface (clock synchronization type x 1 ch) to communicate with the pressure
sensor (SCP1000). Since the general-purpose input/output ports on the S1C6F632 also serve as serial ports, the functions of these
ports must be switched by software if they are to be used as serial ports. Input/output signals from the serial ports are also connected
to the expansion connector. Furthermore, the shared input/output ports (P30, P31) are used for pressure sensor communication-ready
control and power supply control.
Table 9.1 Serial port connection destinations
Interface
Signal name (port pin)
I/O
Connection destination
SCLK (P20)
O
SCK pin for pressure sensor (SCP1000)
Expansion connector (CN2)
Expansion connector (CN3)
*1
ICE connector (CN5
P4
P2)
*2
SOUT (P21)
O
MOSI pin for pressure sensor (SCP1000)
Expansion connector (CN2)
Expansion connector (CN3)
*1
ICE connector (CN5
P4
P2)
*2
SIN (P22)
I
MISO pin for pressure sensor (SCP1000)
Expansion connector (CN2)
Expansion connector (CN3)
*1
ICE connector (CN5
P4
P2)
*2
Clock synchronization type
SS (P23)
O
CSB pin for pressure sensor (SCP1000) (after logic inversion)
Expansion connector (CN2)
ICE connector (CN5
P4
P2)
*2
*1
Connector not provided. Board pattern only.
*2
In the case of S5U1C6F632T2