S5U1C62000A MANUAL
EPSON
203
(S1C60/62 FAMILY ASSEMBLER PACKAGE)
CHAPTER 9: DEBUGGER
tac
(trace area clear)
Function
This command clears program address ranges from the trace area.
Format
>tac [<staddr1> <endaddr1> [... <staddr4> <endaddr4>]]
↵
(direct input mode)
<staddr1–4>: Start address of each specified address range; hexadecimal or symbol (IEEE-695 format only)
<endaddr1–4>:End address of each specified address range; hexadecimal or symbol (IEEE-695 format only)
Condition:
0
≤
staddr(1–4)
≤
endaddr(1–4)
≤
last program memory address
Example
>ta
↵
Trace area:
0000..0fff
... Current trace area
1. set 2. clear 3. clear all ...?
↵
>tac 400 600
↵
... Clears a trace area from 0x400 to 0x600.
>ta
↵
Trace area:
0000..03ff
0601..0fff
1. set 2. clear 3. clear all ...?
↵
>
Notes
• The addresses must be specified within the range of the program memory area available for each
microcomputer model.
An error results if the input one is not a hexadecimal number or a valid symbol.
Error : invalid value.
An error results if the limit is exceeded.
Error : Program address out of range.
• An error results if the start address is larger than the end address.
Error : end address < start address.
• If you input the tac command without any parameter, the entire trace area is clear by default.
• You can use this command for multiple times to clear address ranges from trace area.
GUI utility
[Trace | Trace area …] menu item
When this menu item is selected, a dialog box appears for clearing trace areas. (See the ta command.)