3 FUNCTION OPTION GENERATOR FOG6008
14
EPSON
S5U1C60N08D MANUAL
(DEVELOPMENT SOFTWARE TOOL FOR S1C60N08)
FOUT output
R12 register
0
1
0
V
SS
V
DD
Fig. 3.3.5 Output waveform at R12 FOUT output selection
Select the output specification for the R13
terminal.
Either complementary output or Pch open drain
output may be selected.
When DC output is selected, R13 becomes a
regular output port. When "BUZZER
INVERTED OUTPUT" is selected, inverted
waveform of the R10 buzzer output is generated
from the R13 terminal. The R13 and R10
control bits become buzzer inverted output when
"1" is written to the R13 and R10 registers,
respectively.
*
The buzzer inverted output may not be
selected when the R10 output type (see
Option 8, "R10 specification") is not set to
buzzer. Moreover, at this point, when the
R10 output type is reselected after selecting
buzzer inverted output, the R10 output type
is fixed at buzzer output.
Buzzer output waveform is shown in Figure
3.3.6.
R13 buzzer output
R10/R13 register
0
1
0
V
DD
V
SS
V
DD
V
SS
R10 buzzer output
Fig. 3.3.6 Buzzer output waveform
•
When FOUT output is selected
When FOUT bit (R12 register) is set to "1",
50% duty and V
DD
–V
SS
amplitude square
wave is generated at the specified
frequency. When set to "0", the FOUT
terminal goes low (V
SS
).
A FOUT frequency may be selected from
among 8 types, ranging from 256 or 300 Hz
to 32,768 or 38,400 Hz.
FOUT output is normally utilized to provide
clock to other devices but since hazard
occurs at the square wave breaks, great
caution must be observed when using it.
Output waveform is shown in Figure 3.3.5.
11 R13 specification
*** OPTION NO.11 ***
--- R13 SPECIFICATION ---
OUTPUT SPECIFICATION
1. COMPLEMENTARY
2. P-CH OPEN DRAIN
PLEASE SELECT NO.(1) ? 1
OUTPUT TYPE
1. DC OUTPUT
2. BUZZER INVERTED O/P(R13)
3. BUZZER INVERTED O/P(R10)
PLEASE SELECT NO.(1) ? 2
OUTPUT SPECIFICATION 1. COMPLEMENTARY SELECTED
OUTPUT TYPE 2. BUZZER INVERTED O/P(R13) SELECTED
Содержание S5U1C60N08D
Страница 4: ......