EPSON Perfection4180 Photo
Revision A
DISASSEMBLY/ASSEMBLY
Disassembly Procedure
34
4.2.2 Removal of Housing Upper
1. Remove the TPU Unit.
2. Remove the two screws (CBP, M3x12) that are securing the Housing Upper.
3. Lift the rear side of the Housing Upper. Then, slide it to the front, release the three
hooks, and remove the Housing Upper.
Figure 4-5. Removal of Housing Upper (1)
Figure 4-6. Removal of Housing Upper (2)
Figure 4-7. Hooks
M3x12
Tightening torque 6-8kgfcm
Housing Upper
Hooks