EPSON Perfection 3200 Photo
Revision A
Disassembly and Assembly
DISASSEMBLY AND ASSEMBLY
37
4.2.3 Upper Cover Removal
1.
Release the carriage lock. (See Section 4.2.1.)
2.
Remove the document cover. (See Section 4.2.2.)
3.
Remove the two screws (CBP, M3x8) at the back of the scanner. (See
Figure 4-6.)
4.
While lifting up the upper cover and pulling it forward, disengage the three
hooks at the front of the upper cover, and then remove the upper cover.
5.
Disconnect the connector (CN1) from the SUB_A circuit board. (See Figure
4-8)
Figure 4-6. Upper Cover Removal (1) - Screw Positions
Figure 4-7. Document Cover Removal (2)
Figure 4-8. Upper Cover Removal (3)
C A U T I O N
When removing the upper cover, make sure that the hooks
are properly disengaged so that the tabs do not get broken.
CBP Screws (3x8)
Tightening Torque : 8-10kgfcm
Hooks