![Epson Part Feeding 7.0 IF-80 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/epson/part-feeding-7-0-if-80/part-feeding-7-0-if-80_manual_110802051.webp)
5. Maintenance and Component Replacement
Part Feeding 7.0 IF-80 Rev.3
45
5.3.2 Resetting IP Address
The following procedure explains how to reboot the IF-80 so that is uses the default IP
address, subnet mask and TCP port number to be able to modify the IP address, subnet mask
and TCP port number when they are unknown and cannot be found. Following this
procedure, you are able to connect to the IF-80 with default parameters and then modify
parameters as desired.
Step 1
Remove the hopper.
Unscrew the 4 screws (A) and remove the cover (B).
Use a torx key size 10.
Step 2
Place selector 1 in “on” Position (C)
Step 3
Disconnect and reconnect the power cable. (or switch off and switch on the power on the
IF-80.)
The IF-80 will take the default parameters by the new startup:
IP: 192.168.0.64
SubnetMask: 255.255.255.0
TCP Port: 4001