EPSON Stylus CX1500/ME100
Revision A
DISASSEMBLY AND ASSEMBLY
Disassembly
108
4.3.20 PF Motor
V
External View
Figure 4-52. PF Motor Removal
V
Part/Unit that should be removed before removing PF Motor.
Document Cover / Stacker / Panel Unit / Panel Housing / Scanner Unit /
Housing Upper / Main Board Unit / Housing Middle / Housing Lower (Outer) /
ASF Unit / PS Board Unit / Front Frame / EJ Roller / Housing Lower (Inner)
V
Removal procedure
1.
Remove the screws (x2,
) for securing PF Motor.
2.
Release the hook (x1,
) for securing PF Motor Connector Cable, and then
cut off the banding band.
3.
Remove PF Motor from Main Frame.
C A U T I O N
Do not damage the following locations.
T
Pinion gear of PF Motor
T
Spur Gear 60 of PF Roller
C.B.S 3x6 F/Ni (
TBD
)
PF Motor
Pinion gear
Spur Gear
60
Hook
Banding band
PF Motor
Connector Cable
Содержание ME100
Страница 1: ...EPSON StylusCX1500 ME100 Scanner Printer Copier SEOT04 006 SERVICE MANUAL ...
Страница 8: ...C H A P T E R PRODUCTDESCRIPTION ...
Страница 29: ...C H A P T E R OPERATINGPRINCIPLES ...
Страница 47: ...C H A P T E R TROUBLESHOOTING ...
Страница 72: ...C H A P T E R DISASSEMBLYANDASSEMBLY ...
Страница 110: ...C H A P T E R ADJUSTMENT ...
Страница 115: ...C H A P T E R MAINTENANCE ...
Страница 121: ...C H A P T E R APPENDIX ...
Страница 132: ...EPSON Stylus CX1500 ME100 Revision A APPENDIX Electrical Circuits 132 C572 Main control circuit board ...
Страница 133: ...EPSON Stylus CX1500 ME100 Revision A APPENDIX Electrical Circuits 133 C5xx PSB power supply circuit board ...
Страница 134: ...EPSON Stylus CX1500 ME100 Revision A APPENDIX Electrical Circuits 134 C5xx PSE power supply circuit board ...
Страница 135: ...EPSON Stylus CX1500 ME100 Revision A APPENDIX Electrical Circuits 135 C5xx Panel circuit board ...