Do not install this product where it may be subject to impact or vibration.

Do not install this product in direct sunlight or near a heater vent, fireplace, or other source of heat.

Do not install this product on a slanted ceiling.

Personal injury and/or damage to the equipment could result from dropping or mishandling this product.

Some of the components included with this product may be packaged in plastic bags. Keep plastic bags 
away from small children to avoid any risk of suffocation.

Do not place the components of this product near sources of heat or in direct sunlight.

Make sure nothing blocks the ventilation openings on any of the components. Allow for sufficient heat 
dispersion. Ensure that there is at least 8 inches (20 cm) between any ventilation openings and the walls or 
ceiling.

Where the mains plug is used as the disconnect device, the disconnect device shall remain readily operable.

When unplugging the power cord, handle it carefully. Hold the plug when unplugging the cord.

This product should be operated only from the type of power source indicated on the marking label. If you 
are not sure of the type of power supplied in your (school, business, home), consult your product dealer or 
local power company.

Do not overload wall outlets, extension cords, or integral convenience receptacles as this can result in a risk 
of fire or electric shock.

Keep the system components free from moisture, water, and dust.

Do not let insecticides, benzene, or thinner come in contact with any components of the system.

Never push objects of any kind through openings in the system components as they may touch dangerous 
voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on 
the product.

Except as specifically explained in these instructions, do not attempt to service this product yourself. Refer 
all servicing to qualified service personnel.

Never disassemble or modify the product in any way. Dangerous electrical voltages inside the components 
can severely injure you.

When replacement parts are required, be sure the service technician has used replacement parts specified by 
the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result 
in fire, electric shock, or other hazards.

Do not place the system near high-voltage power lines or sources of magnetism. The system may not 
operate properly.

Содержание AP-60 - Projector Sound Solution

Страница 1: ...AP 60 Installation Guide ...

Страница 2: ...product or third parties for damages losses costs or expenses incurred by purchaser or third parties as a result of accident misuse or abuse of this product or unauthorized modifications repairs or alterations to this product or excluding the U S failure to strictly comply with Seiko Epson Corporation s operating and maintenance instructions Trademarks Epson is a registered trademark and Epson Exc...

Страница 3: ...apparatus near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one...

Страница 4: ... away from hot electrical appliances Contact your dealer if the wires of the power cable become exposed or broken Connect the power cable to a grounded outlet Take the following precautions when handling the plug Failure to comply with these precautions could result in fire or electric shock Do not overload outlets extension cables or multi socket devices Do not insert the plug into the outlet wit...

Страница 5: ...wer of the system and the projector turned off during the installation There is a risk of an electric shock Be aware of the neck strap when using the pendant microphone The neck strap may snap off if handled roughly Never pull the neck strap when it is hung around the neck It may result in injury or accident Cautions Unplug the system from the outlet before cleaning This avoids electric shock duri...

Страница 6: ...tion procedures as outlined in these instructions must be adhered to Failure to do so could result in serious personal injury or death This product should be installed by a professional audio video installer or other qualified professional Epson cannot provide advice concerning construction practices or building codes in your area Prior to installing this product read the installation instructions...

Страница 7: ...u are not sure of the type of power supplied in your school business home consult your product dealer or local power company Do not overload wall outlets extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock Keep the system components free from moisture water and dust Do not let insecticides benzene or thinner come in contact with any components...

Страница 8: ...g the Installation 10 Installing the IR Dome Sensor 11 Install the Mounting Pipe 13 Install the AP 60 14 Install the Projector 19 Attach the Neck Strap 19 Insert Batteries 20 Adjust the Sound 21 Solving Problems 23 Where To Get Help 26 ...

Страница 9: ...g any parts contact Epson as described on page 26 Note The included installation hardware is designed for a 1 5 inch pipe mount You may need additional hardware if your setup varies Additional Accessories You can purchase projectors screens or other accessories from an Epson authorized reseller To find the nearest reseller call 800 GO EPSON 800 463 7766 Or you can purchase online at www epsonstore...

Страница 10: ...lified professional Epson cannot provide advice concerning construction practices or building codes in your area The Installation requires at least two people For added safety install the included guy wires to prevent the AP 60 from falling Ensure that the ceiling is strong enough before installing the wires 3 Install the AP 60 and connect cables See page 14 2 Install the mounting pipe See page 13...

Страница 11: ...reduce the sensitivity and range of the IR dome sensor Do not bound the coaxial cable to any other cables Do not install the IR sensor near strong light sources such as incandescent bulbs halogen lamps fluorescent lights or a window The IR dome sensor must be mounted at least 3 28 feet 1 meter away from fluorescent lights Do not install the IR dome sensor in a dusty environment This can reduce the...

Страница 12: ...h or inadequate installation 1 Bend both ends of the mounting bracket as shown below 2 Securely attach the IR dome sensor to the ceiling Installation varies depending on your building construction 3 Attach the coaxial cable to the IR dome sensor 4 Secure the coaxial cable to the ceiling Note The coaxial cable can also be run in the ceiling instead of securing it to the ceiling For best performance...

Страница 13: ... 60 and your projector If you re installing the AP 60 without a projector the ceiling mount must be designed to support the total weight of the AP 60 approximately 15 2 lbs 6 9 kg 1 Thread the included mounting pipe into your ceiling mount 2 Follow your ceiling mount manufacturer s instructions to secure the pipe to the ceiling mount ...

Страница 14: ... power and video cables through the cable channel as shown below 3 Slide the AP 60 and the lower bracket onto the mounting pipe with the audio control panel facing the front of the room The lower bracket s cutout should line up with the cable channel on the bottom of the AP 60 4 Secure the lower bracket with the M47 5 jam nut as shown below Do not attach the M10 bolt and nut at this time Lower bra...

Страница 15: ...ol panel from the AP 60 and keep it supported at all times Warning Pulling out the audio control panel too quickly or not supporting the audio control panel when it is removed from the AP 60 can permanently damage the cable connections on the back of the audio control panel Remove screws ...

Страница 16: ...he audio cables to the audio control panel 9 Gently slide the audio control panel back into the AP 60 while pulling out any excess cable from the top of the unit Power Microphone RS232 L R HF ANTFD Output CMD Line 2 Line 1 Off On Off Low Hi Rec IR sensor DVD LCP RCA line input 3 5 mm stereo mini jack input 3 5 mm stereo mini jack output ...

Страница 17: ...panel in place 11 Attach the IR dome sensor cable to the top of the AP 60 12 Once the cables are positioned as desired lift the AP 60 and secure the lower bracket with the M10 bolt and nut 13 Tighten the M47 5 jam nut until it s flush with the lower bracket ...

Страница 18: ... the guy wires to a secure location Installation varies depending on your building construction Note When installing the guy wires do not make them too taut This can cause the AP 60 to be unstable on the mounting pipe and lower bracket 16 Connect the power cable to the AP 60 ...

Страница 19: ...secured correctly Follow the instructions included with your projector mount to attach the projector to the mounting pipe Then connect power and video cables to the projector as necessary Attach the Neck Strap 1 Disconnect both ends of the pendant microphone s neck strap 2 Attach the ends of the neck strap to the pendant microphone ...

Страница 20: ...sert Batteries 1 Remove the remote control battery cover 2 Check the battery label and insert the included R6 manganese AA batteries into the remote control 3 Replace the remote control battery cover 4 Open the pendant microphone s battery cover ...

Страница 21: ... equipment to the AP 60 Then follow the steps in this sections to adjust the audio levels 1 Press the P power button on the AP 60 remote control to turn on the system The P power light on the AP 60 turns green 2 Adjust the Microphone 1 Microphone 2 Line 1 and Line 2 gain control knobs to the far left setting to turn the gains all the way down 3 Make sure that all of your audio sources are connecte...

Страница 22: ...e microphone is just below the assistant s collarbone 6 Set the Channel switch to 1 7 Press the power button until it clicks into place The power button turns green 8 Verify that the Mic 1 light on AP 60 is lit 9 Adjust the Gain wheel until the white line on the is next to Up but still visible Emitter Set to Channel 1 Power button White line ...

Страница 23: ...he microphones should be the same volume level 14 Adjust the volume control on the audio device that is connected to Line 1 so that it is 50 to 75 percent of maximum volume If your audio device does not have a volume adjustment continue with step 15 15 Have an assistant play audio from the device that is connected to Line 1 while speaking into the microphone 16 Adjust the Line 1 gain control knob ...

Страница 24: ... time Be sure to turn off unwanted audio sources as necessary My voice isn t loud enough Use the Gain control wheel on the pendant microphone to increase the microphone sensitivity Adjust the master volume Adjust the Microphone gain control knob on the AP 60 External audio devices are too loud Use the Gain control wheel on the pendant microphone to increase the microphone sensitivity Adjust the au...

Страница 25: ...channel selected on the remote control If you re using more than one microphone make sure that each microphone is set to use a different channel Check to see if the IR dome sensor s red power light is lit If it s not contact your maintenance department to check the cable connections My voice isn t loud enough Use the Gain control wheel on the pendant microphone to increase the microphone sensitivi...

Страница 26: ...dialing one of these numbers U S 562 276 4394 6 AM to 6 PM Pacific Time Monday through Friday Canada 905 709 3839 6 AM to 6 PM Pacific Time Monday through Friday Days and hours of support are subject to change without notice Toll or long distance charges may apply Before you call please have this information ready Product name AP 60 and serial number located on the back of the product Proof of pur...

Страница 27: ......

Страница 28: ...Printed in XXX ...

Отзывы: