EPSON AcuLaser CX11/CX11F
Revision B
TROUBLESHOOTING
Printer
222
FIP-51
Panel Message
Service Req E547
Possible parts that caused the error
Troubleshooting
HARNESS-ASSY FEED MAIN
DRIVE ASSY FEED
PWBA TRAY 500
HARNESS-ASSY FEED 1
HARNESS ASSY MAIN
PWBA MCU
LV/HVPS
Step
Check
Yes
No
1
Check of DRIVE ASSY FEED attachment
Is DRIVE ASSY FEED attached correctly?
Go to Step [2].
Re-attach, and go
to step [2].
2
Continuity check of HARNESS-ASSY FEED
MAIN
Disconnect P/J437 from PWBA TRAY CONT.
Do all of the wiring below have normal
continuity?
J437-1
↔
CN1-5
J437-2
↔
CN1-4
J437-4
↔
CN1-2
J437-5
↔
CN1-1
Go to Step [3].
Replace
HARNESS-
ASSY FEED
MAIN.
3
24 VDC power supply check to DRIVE
ASSY FEED
The voltage of P440-2
↔
P440-1 on PWBA
FEED DRV is 24 VDC?
Go to Step [4].
Go to Step [5].
4
Check of FEED MOTOR START signal
The voltage of P440-5
↔
P440-1 on PWBA
FEED DRV is xx VDC when FEED MOTOR
START signal is ON?
Replace DRIVE
ASSY FEED.
Go to Step [10].
5
24 VDC power supply check to PWBA
TRAY 500
The voltage of P435-9/10
↔
P435-7/8 on
PWBA TRAY 500 is 24 VDC?
Replace PWBA
TRAY 500.
Go to Step [6].
6
Continuity check of HARNESS-ASSY FEED 1
Disconnect P/J435 from PWBA TRAY CONT.
Do all of the wiring below have normal
continuity?
J435-10
↔
P608-1 (connector on Feeder to
be connected to the printer)
J435-9
↔
P608-2
J435-8
↔
P608-3
J435-7
↔
P608-4
Go to Step [7].
Replace PWBA
TRAY 500.
7
Continuity check of HARNESS ASSY MAIN
Disconnect P/J421 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J421-1
↔
J608-10 (connector on the printer
to connect Feeder)
J421-2
↔
J608-9
J421-3
↔
J608-8
J421-4
↔
J608-7
Go to Step [8].
Repair broken or
shorted part.
8
24 VDC power supply check to PWBA MCU
The voltage of P410-5/6
↔
P410-7/8 on
PWBA MCU is 24 VDC?
Replace PWBA
MCU.
Go to Step [9].
9
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-5
↔
J502-5
J410-6
↔
J502-6
J410-7
↔
J502-7
J410-8
↔
J502-8
Replace LV/
HVPS.
Repair broken or
shorted part.
10
5 VDC power supply check to PWBA TRAY
500
The voltage of P435-6
↔
P435-5 on PWBA
TRAY CONT is 5 VDC?
Replace PWBA
TRAY 500.
Go to Step [11].
Step
Check
Yes
No
manuals4you.com
manuals4you.com
Содержание AcuLaser CX11 Series
Страница 1: ...EPSON AcuLaserCX11 CX11F Color Multi Function Page Printer SERVICE MANUAL SEOT04007 ...
Страница 11: ...Schematic Diagram of Safety System ...
Страница 15: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 75: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 126: ...C H A P T E R 3 TROUBLESHOOTING manuals4you com manuals4you com ...
Страница 297: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 528: ...C H A P T E R 5 ADJUSTMENT manuals4you com manuals4you com ...
Страница 543: ...C H A P T E R 6 MAINTENANCE ...
Страница 562: ...C H A P T E R 7 APPENDIX manuals4you com manuals4you com ...
Страница 618: ...IR A ASSY manuals4you com manuals4you com ...
Страница 619: ...IR B ASSY ...
Страница 620: ...1 4 3 01 1 01 2 2 DOC COVER manuals4you com manuals4you com ...
Страница 621: ...2 3 4 5 6 7 8 9 10 11 1 13 11 17 18 12 22 14 19 16 20 21 15 11 11 13 ADF UNIT ASSY ...
Страница 624: ...PAPER GUIDE ASSY manuals4you com manuals4you com ...
Страница 627: ...Board C588MAIN BOARD Model Aculaser CX11 CX11F Sheet 1 of 6 Rev A ...
Страница 628: ...Board C588MAIN BOARD Model Aculaser CX11 CX11F Sheet 2 of 6 Rev A manuals4you com manuals4you com ...
Страница 629: ...Board C588MAIN BOARD Model Aculaser CX11 CX11F Sheet 3 of 6 Rev A ...
Страница 630: ...Board C588MAIN BOARD Model Aculaser CX11 CX11F Sheet 4 of 6 Rev A manuals4you com manuals4you com ...
Страница 631: ...Board C588MAIN BOARD Model Aculaser CX11 CX11F Sheet 5 of 6 Rev A ...
Страница 632: ...Board C588MAIN BOARD Model Aculaser CX11 CX11F Sheet 6 of 6 Rev A manuals4you com manuals4you com ...