4.
Hold down the tabs to release the LATCH FRONTs, and remove the LATCH FRONTs from the
PLATE LATCH.
Kmy03012EB
4)-2
4)-2
4)-1
4)-1
LATCH FRONT
LATCH FRONT
PLATE LATCH
HARNESS ASSY-CON F
Open and close the COVER ASSY FRONT to check if the harnesses routed through the
DUCT DRV PH are under no-load conditions.
1.
Disconnect the connectors (P/J OP2, P/J OP3) of the HARNESS ASSY-CON F (main unit side).
2.
Release the HARNESS ASSY-CON F from the DUCT DRV PH.
Make sure that the ground wire (green), HARNESS ASSY-CON F (white), and HARNESS
ASSY FRONT COVER (black), which are coming out of the COVER ASSY FRONT, are
routed as shown in figure-C.
NEXT>>
D
Kmy03092EA
Figure-C
HARNESS ASSY-CON F (White)
Gap
Gap
HARNESS ASSY FRONT
COVER (Black)
Ground Wire
(Green)
1)
2)