Printer Main Parts Disassembly and Assembly
202
4.5.20 Rack
1.
Remove the High Voltage Unit (HV). (p.188)
2. Remove the HV Contact Assy. (3 screws)
(See
“Figure 4-57 (p.202)”)
3. While supporting it with your hand, rotate the Rack to a position where you can see
through the cut area of the frame the screw securing a toner cartridge mounting frame
on the Rack.
4. Remove the screws securing the toner cartridge mounting frame. (4 screws in total)
(See
“Figure 4-58 (p.202)”)
5. Remove the Rack Fulcrum Cover. (2 screws)
(See
“Figure 4-59 (p.202)”)
6. Separate the toner cartridge mounting frame from the Rack and take them out through
cut areas of the frame, respectively.
(See
“Figure (p.202)”)
Figure 4-57. Removing the HV Thermal Assy
Figure 4-58. Removing the Screws securing the Toner Cartridge Mounting Frame
Figure 4-59. Removing the Rack Fulcrum Cover
Содержание AcuLaser C1900
Страница 1: ...EPSON AcuLaserC1900 AcuLaserC900 A4 Color Page Printer SERVICE MANUAL ROSCO SEPG02003 ...
Страница 21: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 87: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 122: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 166: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 208: ...C H A P T E R 5 ADJUSTMENT ...
Страница 217: ...C H A P T E R 6 MAINTENANCE ...
Страница 219: ...C H A P T E R 7 APPENDIX ...
Страница 260: ......
Страница 261: ......
Страница 262: ......
Страница 263: ......
Страница 264: ......
Страница 265: ......
Страница 266: ......
Страница 267: ......
Страница 268: ......
Страница 269: ......
Страница 270: ......