background image

Date : 

1.How to replace the battery

Please use the specified battery to keep the stable performance for a long time.

Please install the minus part of the battery towards inside of the watch.

 

 

Install the battery under the circuit cover as illustrated below Fig.[1] and Fig.[2].

System-reset is not required.

2.How to remove the stem

3.Attention to adjust the date

Don't touch the date disks.

When adjusting the date, don't turn the date disk directly by finger.

4.How to set the hands

Do not turn the hand forcibly.

Set the hour and minute hands on the date between "02-08".

5.How to remove the hands

When removing the hands, use exclusive fork-shaped tools.

Do not remove the dial under the condition that any hands are set.

6.How to test the accuracy

When measuring the time accuracy, use specified Quartz Tester and change the gate time in 10 seconds.

When installing or changing the battery, it is recommended to remove two battery clamp screws first,
then remove the battery clamp not to damage the movement parts.
If you install the battery without removing the battery clamp, please install the battery from [

] direction

as illustrated below Fig.[1].

After installing the battery, set the current time and then set the 1/5 second chronograph hand and
minute chronograph hand at "0" position.

When removing the stem, pull out the crown at 1st click position and then remove the stem while
pressing the hollow portion of setting lever by tweezers. (Refer to the Fig.[3].)

Each hand moves at step interval. Set the each hand at correct position according to the scale on the
dial in order not to make a mistake in reading time.

Cal.

YM04A

Attention for assembly

15/Dec./'17

Rev. :  03

A

Battery

Battery clamp

Circuit cover

Fig.[2] A section

Fig.[1]

Fig.[3] Crown pulled out at 1st click

P.8 

Содержание 711001

Страница 1: ...Watch Movement Specification and Drawing CHRONOGRAPH Cal YM04A Movement Size Casing Diameter Height Battery Life 12 Ø 27 0mm 4 93mm 5 years ...

Страница 2: ...e Specifications 02 1 Appearance 02 2 Casing 03 3 Hand fitting 02 4 Hand setting stem 02 5 Dial 01 6 Holding ring for dial 01 7 Attention for assembly 03 8 Attention of casing part structure 02 9 Operation 01 01 10 01 Operation 02 01 10 02 ...

Страница 3: ...and 0 03μN m Minute chronograph hand 0 03μN m 1 5 second chronograph hand 0 09μN m Minute hand 0 7μN m Moment of Inertia 1 5 second chronograph hand less than 0 2μg m 5 BATTERY Type Size Silver oxide battery φ9 5mm t 2 73mm Recommended battery SR927SW Nominal voltage 1 55 V Battery life Approx 5 years 2 hours chronograph operation per day Driving current consumption Approx 0 80μA Operation stoppin...

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ...e specified Quartz Tester and change the gate time in 10 seconds When installing or changing the battery it is recommended to remove two battery clamp screws first then remove the battery clamp not to damage the movement parts If you install the battery without removing the battery clamp please install the battery from direction as illustrated below Fig 1 After installing the battery set the curre...

Страница 11: ...en hour hand and minute hand Use the specified holding ring for dial to prevent rotation of the movement inside of the case in order to stabilize the button operation Refer to the Holding ring for dial page instruction as to the shape and tolerance Use the metal case to prevent from the movement mal function by static electricity Cal YM04A Attention of casing part structure 31 Jul 14 Rev 02 P 9 ...

Страница 12: ...tedly to set it to 0 position Press 2H button for 2 seconds Press 4H button repeatedly to set it to 0 position Push crown back to normal position Cal Operation 01 31 Jul 14 Rev 01 YM04A Minute chronograph hand turns a full round and can now be set to correct 0 position 1 5 second chronograph hand turns a full round and can now be set to correct 0 position 1 2nd click Time setting 1 Crown position ...

Страница 13: ...ime measurement Split time measurement Cal Operation 02 31 Jul 14 Rev 01 YM04A Start Stop Reset 2H button 2H button 4H button Start Stop Restart 2H button 2H button 2H button 2H button 4H button Start Split Split release 2H button 4H button 4H button 2H button 4H button Stop Reset Reset Stop Restart and stop of the chronograph can be repeated by pressing 2H button Measurement and release of split ...

Отзывы: