5.3 Maintenance
The following inspections and maintenance tasks are recommended at
least two times per year for best controller performance.
Check that the controller is securely mounted in a clean and dry
environment.
Check that the air flow and ventilation around the controller is not
blocked. Clear all dirt or fragments on the heat sink.
Check all the naked wires to make sure insulation is not damaged for
serious solarization, frictional wear, dryness, insects or rats etc.
Maintain or replace the wires if necessary.
Tighten all the terminals. Inspect for loose, broken, or burnt wire
connections.
Check and confirm that LED digital tube is consistent with required.
Pay attention to any troubleshooting or error indication .Take
necessary corrective action.
Confirm that all the system components are ground connected
tightly and correctly.