15.3 Flip/Flop 

Operation 

 

Two units can be mounted close to each other to form a flip-
flop operation, where the beacons will flash alternately. To 
achieve this mode of operation, fit a pin header to the flip- 
flop header pins on the electronics board, i.e. the two header 
pins are shorted together, on one of the two beacons. The 
first flash on the beacon that has the header fitted will be 
delayed by ½ second. The two beacons will then flash 
alternately every ½ a second. 

 

 

 
 

16) Interchangeable & Spare Parts 

 

 

The beacon cover is interchangeable, contact E2S Ltd for a 
replacement cover available in various colours.  

 

To change the cover, unscrew the M5 socket head screws 
and remove the M5 screws, M5 spring & flat washers.  

 

Fig. 11 Removal of cover 

 

Remove the guard and replace the old cover with the new 
cover.  

 

Fig. 12 Changing of cover 

Fit the guard back on to the cover and casting, align the 
holes of the guard, cover and casting. To reattach the cover, 
the fixings MUST be in the order shown in figure 12.    

 

 

Fig. 13 Cover and Guard Fixtures 

 

17) Maintenance, Overhaul & Repair 

 

Maintenance, repair and overhaul of the equipment should 
only be carried out by suitably qualified personnel in 
accordance with the current relevant standards: 

 

EN60079-19 
IEC60079-19 

Explosive atmospheres - Equipment repair, 
overhaul and reclamation 

 

EN 60079-17 
IEC60079-17 

Explosive atmospheres - Electrical 
installations inspection and maintenance 

 

To avoid a possible ELECTROSTACTIC CHARGE the unit 
must only be cleaned with a damp cloth. 

 

Units must not be opened while an explosive atmosphere is 
present. 

 

If opening the unit during maintenance operations a clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 
Flameproof threaded joints and cemented joints are not 
intended to be repaired. 

 
 
 

Warning –

 

Hot surfaces. External surfaces 

and internal components may be hot after 
operation, take care when handling the 
equipment. 

Header Pins shorted

Flip / Flop Pin Header 

M5x16 Hex Socket Screw 

M5 Spring Washer 

M5 Plain Washer 

Guard 

Cover

 

M5x16 Hex 
Socket Screw 

Old 
Cover 

New 
Cover

 

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание BExCS110-05D-P DC012

Страница 1: ...e gas air mixture likely to occur in normal operation Zone 2 Explosive gas atmosphere not likely to occur in normal operation but may be present for short periods Gas Groupings Group IIA Propane Group...

Страница 2: ...the unit The BEx combined sounder beacon should be secured to any flat surface using the three 7mm fixing holes on the stainless steel U shaped mounting bracket See Figure 1 The required angle can be...

Страница 3: ...o the M20 entries Any other adapters used must be suitably rated and ATEX IECEx certified adapters 10 Earthing Both AC and DC combined sounder beacon units must be connected to an earth The units are...

Страница 4: ...hing 12 2 1 Units First Stage Tones Stage one S1 Operation Simply connect the supply voltage to the L and N supply terminals see fig 4 12 2 2 AC Units Second and Third Stage Tone Selection To select t...

Страница 5: ...age 3 tone For units set up for ve switching refer to 13 3 Stage two S2 Operation Power ve and ve link a ve supply line to the S2 terminal Dip switch alters stage 2 tone Stage three S3 Operation Power...

Страница 6: ...unit should be used to link the supply from the interconnecting terminals on the beacon board down to the supply terminals on the sounder board 15 Settings 15 1 Tone Selection The sounders have 32 di...

Страница 7: ...n the order shown in figure 12 Fig 13 Cover and Guard Fixtures 17 Maintenance Overhaul Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personne...

Страница 8: ...e 5 15 Continuous at 800Hz 0 1 1 1 0 Tone 2 Tone 5 16 Intermittent 660Hz 150mS on 150mS off 1 1 1 1 0 Tone 18 Tone 5 17 Alternating 544Hz 100mS 440Hz 400mS 0 0 0 0 1 Tone 2 Tone 27 18 Intermittent 660...

Отзывы: