© EPS Stromversorgung in 2022, this information is subject to change without notice
52
30000800_manual_psb_10000_4u_30kw_en_04
Group
Parameters & description
USB logging
Log file separator format
Defines the format of CSV files generated from logging files (also see
and
3.5.8). This setting
also affects other features where a CSV file can be loaded or saved.
•
US
= Comma as column separator (US standard for CSV files)
•
Default
= Semicolon as column separator (german/european standard for CSV files)
Logging with units (V,A,W)
CSV files generated from USB logging by default add physical units to values. This can be deactivated
here.
USB logging
Activates/deactivates logging to USB stick. For more information refer to
Logging interval
Defines the time between two records in the log file. Selection: 500 ms, 1 s, 2 s, 5 s
Start/stop
Defines how the USB logging is started and stopped.
•
Manual
= Logging only starts and stops upon user interaction on the HMI, by accessing touch button
in the quick menu.
•
At DC on/off
= Logging starts and stops with every change of state on the DC terminal, no matter if
caused by the user, software or a device alarm. Attention: Every next start will create a new log file.
Reset / Restart
Reset device to defaults
This touch area will initiate a reset of all settings (HMI, profile etc.) to factory default.
Restart
Triggers a warm start
3.5.3.2
Sub menu “Profiles”
See
“3.10. Loading and saving user profiles”
.
3.5.3.3
Sub menu “Overview”
This menu page displays an overview of the set values (U, I, P or U, I, P, R), device alarm thresholds, event settings, adjustment
limits, as well as an alarm history which lists the number of device alarms that occurred since the device has been powered.
3.5.3.4
Sub menu “About HW, SW, ...”
This menu page displays an overview of device relevant data such as serial number, article number etc.
3.5.3.5
Sub menu “Function Generator”
See
“3.11. The function generator”.
3.5.3.6
Sub menu “Communication”
This sub menu offers settings for digital communication via the built-in interfaces USB and Ethernet and also for the optional
interface modules of IF-AB series.
There are furthermore adjustable communication timeouts. For more information about these timeout refer to the external,
on USB stick included documentation “Programming guide ModBus & SCPI”.