© EPS Stromversorgung in 2022, this information is subject to change without notice
48
30000800_manual_psb_10000_4u_30kw_en_04
3.5
Manual operation
3.5.1
Switching on the device
The device should, as far as possible, always be switched on by putting the rotary switch on the front of the device to position
1. Alternatively this can take place using an external cutout (contactor, circuit breaker) of suitable current capacity.
After switching on, the display will first show some device related information (model, firmware versions etc.) and then a
language selection screen for 3 seconds. A few seconds later it will show the main screen.
In the
Settings
menu (also see section
“3.5.3. Configuration via the menu”
) in the group
DC terminal
is an option
State after
power ON
in which the user can determine the condition of the DC output after power-up. Factory setting here is
Off
, mean-
ing that the DC output on power-up are always switched off.
Restore
means that the last condition will be restored, either on
or off, so the selection here must be considered carefully.
All set values are always saved and restored.
For the time of the start phase the analog interface can signal undefined statuses on its digital outputs.
This must be ignored until the device has finished booting and is ready to work.
While manually operated and while also being connected to any remote control equipment via any of
the interfaces, the device could be taken over into remote control anytime without warning or request
for confirmation. It’s thus recommended to block remote control by activating the ‘Local’ mode for the
duration of manual operation.
3.5.2
Switching the device off
The device is switched off be putting the power switch on the front in position 0. Doing so will cause two things: a) the im-
mediate storage of the last condition of the DC output and the most recent set values and b) the occurrence of a PF alarm
(power fail) which can be ignored. The DC output is also immediately switched off and after a certain stopping time (up to 30
seconds) the display and the fans will go off and then the device is completely powered off.
The power switch on the front cuts the device physically from the AC grid when in position 0. It thus qual-
ifies as a separator.
3.5.3
Configuration via the menu
The settings menu is meant for the configuration of all operating param
-
eters which are not constantly required. The menu is accessed by finger
touch on the
Menu
touch area, but only while the DC terminal is switched
off. See figure to the right.
While the DC terminal is switched on the settings menu will not be
shown, but some status information.
Menu navigation is also done by finger touch. Inside menus, all values
are adjusted using the numeric pad that pops up when tapping a value.
Many settings are self-explanatory, others are not. Those will be ex-
plained on the pages following.