Analog interface
This 15 pole D-sub socket on the rear side of the device is provided for remote control
of the device via analog or digital signals.
If remote control is in operation this analog interface can only be used alternately to
the digital interface. However, monitoring is always available.
The input voltage range of the set values and the output voltage range of the monitor
values, as well as reference voltage level can be switched in the settings menu of the
device between 0-5 V and 0-10 V, in each case for 0-100%.
Figure 4 - Analog interface
1.9.10
“Share BUS” connector
The two BNC sockets (50 Ω type) labeled “Share BUS” form a digital, passed-through
Share bus. This bus is bidirectional and connects the bus master unit via “Share BUS
Output” to the next slave unit (“Share BUS Input”) etc., for use in parallel operation
(master-slave). BNC cables of suitable length can be obtained from us or electronics
stores.
Basically, all 10000 series are compatible on this Share bus, though only connection
of the same device type, i. e. power supply with power supply or electronic load with
electronic load is supported by the devices for master-slave.
For a PSB 10000 series device, different or identical PSB 10000 series models can
be used as slave units. A PSB 10000 device can furthermore be the master of PSBE
10000 devices.
Figure 5 - Share bus
1.9.11
“Sense” connector (remote sensing)
In order to compensate for voltage drops along the DC cables to the load or external
source, the Sense input (2 plugs included in delivery, one each for positive and nega-
tive pole) can be connected to the load resp. external source. The maximum possible
compensation is given in the technical specifications.
In a master-slave system it’s intended to wire remote sensing only
to the master which would then forward the compensation to the
slaves via Share BUS.
The Sense cover must be installed during operation, because
there can be hazardous voltage on the sense lines! Reconfigu
-
ration on the Sense connectors is only permissible if the device
is disconnected from AC supply and all DC sources!
Figure 6- Remote sensing connectors