background image

 

  8 

MOTOR CONTROL BOARD 

DESCRIPTION OF FUNCTION SWITCHES 

 

SETTING 

SWITCH# 

 

 

OPEN (OFF) 

P1: 

Requires that open signal be 
set, then reset prior to 
opening gate. 

CLOSED(ON) 

P1: 

When other conditions allow, 
initiates immediate opening 
after setting of open input. 

OPEN (OFF) 

P2: 

Requires that close signal be 
set, then reset prior to 
closing gate. 

CLOSED (ON) 

P2: 

When other conditions allow, 
initiates immediate closure 
after setting of close input. 

CLOSED (ON) 

LATCH: 

Causes immediate closing of 
gate following setting and 
resetting of safety while gate 
is on open limit, if open 
signal in not present. 

CLOSED (ON) 

INTERRUPT: 

Stops all gate movement 
when safety is set, hold until 
safety is reset. 

OPEN (OFF) 

INTERRUPT: 

Stops gate from closing 
when safety is set. Prevents 
closing until safety is reset. 

CLOSED (ON) 

SEQUENCE: 

When gate is on open limit, 
will initiate closure after 
receiving open signal. 

CLOSED (ON) 

REVERSE: 

Causes gate to open 
following a stop or safety 
input, unless gate is on close 
limit. 

CLOSED (ON) 

WAIT: 

Causes a 2 second delay in 
any change in gate motion 
direction. 

OPEN (OFF) 

CLOSE TIMER: 

Starts when gate reaches 
open limit, if open signal is 
not present and safeties are 
reset. Open input and 
safeties when on will hold 
timer off until cleared. 

OPEN (OFF) 

BRAKE: 

Provides power to opposite 
motor winding momentarily 
upon reaching either limit 
switch. 

 

NOTE: On all configurations, switch 9 must be off for the brake to be active, and switch 8 must be off for closing 
timer to be active. 

 

Содержание 301

Страница 1: ...REVA16 ...

Страница 2: ... INFORMATION OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS ACCESSORY CONNECTIONS MOTOR CONTROL SCHEMATIC INSTALLATION LAYOUT EXAMPLES REVERSE OPERATION MASTER SLAVE CONNECTIONS MAINTENANCE PARTS LIST TROUBLE SHOOTING 1 2 3 4 4 5 7 8 9 10 11 13 14 15 24 25 ...

Страница 3: ...PEDESTRIANS is recommended NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE ARM Install safety devices such as loops and loop detectors safety edges and or photo beams in all installations to prevent the gate from closing on a vehicle Do not install the gate operator in a location where the arm can come within 16 of a stationary object The gate must be installed in a location so that enough clearan...

Страница 4: ...NG MECHANISM The gate arm is operated by a HP instant reversing motor through a heavy duty speed reducer with a 60 1 ratio The gate arm flange is connected directly to the main shaft Adjustable cams are provided to limit gate arm travel All internal parts are zinc plated to prevent rusting ELECTRICAL CONTROLS The parking gate uses a self contained solid state plug in controller The field wiring co...

Страница 5: ... requirements for each of the four UL325 classes Exception An operator for a vehicular barrier arm that is not intended to move toward a rigid object closer than 16 inches 407 mm is not required to be provided with means to protect against entrapment Usage Class Barrier Arm Gate Primary Type Secondary Type Vehicular I and II Vehicular III Vehicular IV A or C A B1 B2 or C A B1 B2 C or D A B1 B2 C o...

Страница 6: ... visible to the operator and only when the area is free of people and obstructions The entrance is for vehicles only Pedestrians must use separate entrance 7 KEEP GATES PROPERLY MAINTAINED Read the owner s manual Have a qualified service person make repairs to the gate hardware 8 SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF INJURY TO PERSONS USE THE OPERATOR ONLY WITH INTENDED LENGTH OF G...

Страница 7: ...5 Open the top cover and install speed reducer breather plug 6 Connect interconnecting wires to the other parts in the system by referring to the field wiring diagram page 5 Be sure all power is OFF when hooking up L1 and Neut All electrical wiring must be connected exactly as indicated in the wiring diagrams 7 Turn the circuit breaker in gate housing OFF The gate is now ready to operate Turn powe...

Страница 8: ...6 ...

Страница 9: ...ton is used for closing the gate Free Open Vehicle Detector Connect power according the manufacturer s instructions Connect presence relay common to terminal 7 Connect presence relay normally open to terminal 10 Connect loop wires from detector and actual loop wires to terminals 23 and 24 OPENING DEVICE CONNECTIONS All opening devices such as card readers cash registers radio receivers push button...

Страница 10: ...fety is set hold until safety is reset OPEN OFF 4 INTERRUPT Stops gate from closing when safety is set Prevents closing until safety is reset CLOSED ON 5 SEQUENCE When gate is on open limit will initiate closure after receiving open signal CLOSED ON 6 REVERSE Causes gate to open following a stop or safety input unless gate is on close limit CLOSED ON 7 WAIT Causes a 2 second delay in any change in...

Страница 11: ...G AS CLOSING LOOP IS ACTIVATED LIMIT SWITCH LIGHTS CLOSE ILLUMINATES WHEN GATE IS OPEN SHOWING WHAT NEXT FUNCTION IS GOING TO BE OR WHEN GATE IS IN MOTION EXTINGUISHES WHEN GAE IS CLOSED May be dim OPEN ILLUMINATES WHEN GATE IS CLOSED SHOWING WHAT NEXT FUNCTION IS GOING TO BE OR WHEN GATE IS IN MOTION EXTINGUISHES WHEN GATE IS OPEN May be dim STOP ALWAYS ILLUMINATE UNLESS STOP INPUT IS PRESENT OPE...

Страница 12: ...10 ...

Страница 13: ...rd reader which causes the gate arm to rise When the vehicle leaves loop 1 the gate will return to the down position Suggested control board switch setting 1 2 3 6 8 ON INCOMING POWER 115 VAC 60 Hz 20 Amps NOTE THE LOOP IS CENTERED IN THE LANE MAKE SURE THERE IS AT LEAST 16 INCHES OF CLEARANCE BETWEEN THE GATE ARM AND ANY RIGID OBJECTS ...

Страница 14: ... from the free side loop 2 will be activated which will raise the gate arm permitting the vehicle to drive through As the vehicle leaves loop 1 the gate will automatically return to the down position Suggested control board switch setting 1 3 6 8 ON Auxiliary Board in controller is required for this configuration in units manufactured prior to May 2008 INCOMING POWER 115 VAC 60 Hz 20 Amps NOTE THE...

Страница 15: ...or and swap terminal 1 with terminal 2 white and green red wires Re install the motor Manually turn the pulley until the gate arm flange turns 180 Rotate limit switch cams and adjust accordingly Make all final adjustments and tests before installing the gate arm MASTER SLAVE INSTALLATION For locations with very wide lanes two gates can be installed in a master slave configuration Gates are install...

Страница 16: ...ND SENSITIVITY AND ADJUST AS NECESSARY EVERY 60 DAYS 1 CHECK AND TIGHTEN ALL NUTS BOLTS AND SCREWS THROUGHOUT THE GATE OPERATOR 2 CHECK THE UP AND DOWN LIMIT SWITCHES FOR ADJUSTMENT AND TIGHTNESS DO NOT MAKE ANY ADJUSTMENTS UNLESS THE GATE CIRCUIT BREAKER IS IN THE OFF POSITION 3 CHECK THE BELT TENSION AND PULLEYS FOR ALIGNMENT AND WEAR EVERY 12 MONTHS DRAIN AND REFILL THE SPEED REDUCER WITH SYNTH...

Страница 17: ...15 ...

Страница 18: ...LT GATE ARM FLANGE COVER GATE ARM FLANGE 3 8 16 X 1 CARRIAGE BOLT 8 X 2 TAPER PIN 1 FLANGE BEARING 28 X ALLEN HD SET SCREW 3 8 SPLIT LOCK WASHER 3 8 16 HEX NUT 1 OUTPUT SHAFT 5 16 18 ALLEN HD SET SCREW X X 1 KEYSTOCK 60 1 SPEED REDUCER AIR BREATHER 5 16 18 X ALLEN HD SET SCREW LIMIT SWITCH CAM 10 32 X RD HD MS 10 SPLIT LOCK WASHER 10 FLAT WASHER 6 32 X 1 RD HD M S LIMIT SWITCH MTG BRACKET MICRO SW...

Страница 19: ...D OMIT 1 1 1 1 1 1 1 908 24 542 4L400 9000 27 9000 S14 908 3 542 4L320 9000 S10 12 SPEED REDUCER PULLEY 4L400 V BELT COUNTER BALANCE ASSEMBLY 14 FOOT WOODEN GATE ARM 8 SPEED REDUCER PULLEY 4L320 V BELT 10 FOOT WOODEN GATE ARM PARTS LIST SUPPLEMENT 301 16 PARKING GATE MAIN FRAME ADD OMIT 1 1 1 1 1 1 1 908 24 542 4L400 9000 28 9000 S16 908 3 542 4L320 9000 S10 12 SPEED REDUCER PULLEY 4L400 V BELT CO...

Страница 20: ...USING I D 1 2 3 4 5 6 7 QUANT 1 1 1 1 1 1 1 PART NUMBER 9000 1 1 015 312 18WN 1051 24 1051 24A 806 1A 806 1 806 1B DESCRIPTION MAIN HOUSING PARKING GATE 5 16 8 WING NUT EPS NAME PLATE EPS ELECTRICAL NAME PLATE CAM LOCK NUT CAM LOCK KEY ...

Страница 21: ...19 ...

Страница 22: ...12 750H 074 4 016 2 016 375 16NA 908 26 542 4L360 DESCRIPTION 10 TWO PIECE ARM ASSEMBLY 12 TWO PIECE ARM ASSEMBLY SANDWICH PLATES ROD END BEARING SPLIT LOCK WASHER 20 HEX NUT 5 8 11 NYLOCK HEX NUT 13 NYLOCK HEX NUT USS FLAT WASHER GATE ARM FLANGE 8 X 2 TAPERED PIN 20 THREADED ROD SPACER ID X 7 8 OD X 1 13 HEX NUT 3 8 16 X 1 CARRIAGE SCREW FOLDING GATE ARM BRACKET 13 X 3 HEX HD SPACER ID X 7 8 OD X...

Страница 23: ...DESCRIPTION 6 X NYLON SPACER 1 OHM 55 WATT RESISTOR 10 AMP CIRCUIT BREAKER SPDT TOGGLE SWITCH 3 TERMINAL BLOCK 12 TERMINAL BLOCK RUBBER GROMMET PLASTIC BUSHING MARKER STRIP L1 NEUT GND MARKER STRIP 1 12 MARKER STRIP 13 24 19 CONDUCTOR CABLE 3 CONDUCTOR MOTOR CABLE 4 CONDUCTOR LIMIT SWITCH CABLE DECAL GATE RAISE LOWER DECAL CIRCUIT BREAKER DECAL REBOUND SENSITIVITY 18 TERMINAL EDGE CONNECTOR TERMIN...

Страница 24: ...ector for proper tuning and loop wiring for continuity Make sure all terminal connections are properly connected If the gate still does not open jumper between the common and open terminals on the terminal strip Failure at this point indicates that the malfunction is in the gate controller or in the terminal connection s 4 If the gate still will not operate disconnect the main power Check all term...

Отзывы: