PS 9000 1U Series

3.5.4  Remote control via the analog interface (AI)

3.5.4.1  General

The built-in, up to 1500 V DC galvanically separated, 15-pole analog interface (short: AI) is on the rear side of the 

device offers the following possibilities:

• 

Remote control of current, voltage and power

• 

Remote status monitoring (CC/CP, CV)

• 

Remote alarm monitoring (OT, OVP)

• 

Remote monitoring of actual values

• 

Remote on/off switching of the DC output

Setting the 

three

 set values via the analog interface always takes place concurrently. It means, that for example 

the voltage can not be given via the AI and current and power set by the rotary knobs, or vice versa. 
The OVP set value and other supervision (events) and alarm thresholds cannot be set via the AI and therefore 

must be adapted to the given situation before the AI is put in operation. Analog set values can be fed in by an ex-

ternal voltage or generated by the reference voltage on pin 3. As soon as remote control via the analog interface 

is activated, the values displayed will be those provided by the interface.
The AI can be operated in the common voltage ranges 0...5 V and 0...10 V in each case 0...100% of the nominal 

value. The selection of the voltage range can be done in the device setup. See section 

„3.4.3. Configuration in the 

setup menu“ 

for details.

The reference voltage sent out from Pin 3 (VREF) will be adapted accordingly and is then:

0-5 V

: Reference voltage = 5 V, 0...5 V set values (VSEL, CSEL, PSEL) correspond to 0...100% nominal values, 

0...100% actual values correspond to 0...5 V at the actual value outputs (CMON, VMON).

0-10 V

: .Reference voltage = 10 V, 0...10 V set values (VSEL, CSEL, PSEL) correspond to 0...100% nominal values, 

0...100% actual values correspond to 0...10 V at the actual value outputs (CMON, VMON).
Input of excess set values (e.g. >5 V in selected 5 V range or >10 V in the 10 V range) are clipped by setting the 

set value at 100%.

Before you begin, please read these important notes for use of the interface:

• 

Analog remote control of the device must be activated by switching pin “REMOTE” (5) first. Only exception is 

pin REM-SB, which can be used independently since KE firmware version 2.03

• 

Before the hardware is connected that will control the analog interface, it shall be checked that it can’t provide 

voltage to the pins higher than specified

• 

Set value input, such as VSEL, CSEL and PSEL, must not be left unconnected (i.e. floating)

• 

It is always required to provide all three set values at once. In case any of the set values is not used for adjust-

ment, it can be tied to a defined level or connected to pin VREF (solder bridge or different), so it gives 100%

The analog interface is galvanically separated from DC output. Therefore do not con-

nect any ground of the analog interface to the DC- or DC+ output!

3.5.4.2  Resolution and sample rate

The analog interface is internally sampled and processed by a digital microcontroller. This causes a limited resolu-

tion of analog steps. The resolution is the same for set values (VSEL etc.) and actual values (VMON/CMON) and 

is 26214. Due to tolerances, the truly achievable resolution can be slightly lower.
There is furthermore a max. sample rate of 500 Hz. It means, the device can acquire analog set values and states 

on digital pins 500 times per second.

3.5.4.3  Acknowledging device alarms

Device alarms (see 

3.6.2

) are always indicated in the front display and some of them are also reported as signal on 

the analog interface socket (see 

3.5.4.4

), for example the overvoltage alarm (OV), which is considered as critical.

In case of a device alarm occurring during remote control via analog interface, the DC output will be switched off 

the same way as in manual control. While alarms OT and OV can be monitored via the corresponding pins of the 

interface, other alarms can’t. Those could only be monitored and detected via the actual values of voltage and 

current being all zero contrary to the set values.
All device alarms (OT, OV, PF, OCP and OPP) have to be acknowledged, either by the user of the device or by the 

controlling unit. Also see 

„3.6.2. Device alarm handling“. 

Acknowledgement is done with pin REM-SB switching 

the DC output off and on again, means a HIGH-LOW-HIGH edge (min. 50ms for LOW), when using the default 

level setting for this pin.

Содержание 06230400

Страница 1: ...Revision 05 Date 08 2016 Operating Guide PS 9000 1U DC Laboratory Power Supply Attention This document is only valid for devices with firmware KE 2 07 and HMI 2 03 or higher For availability of up dat...

Страница 2: ......

Страница 3: ...2 3 8 Connecting the Share bus 25 2 3 9 Connecting the analog interface 26 2 3 10 Connecting the USB port 26 2 3 11 Initial commission 26 2 3 12 Initial network setup 27 2 3 13 Commission after a firm...

Страница 4: ...ermany PS 9000 1U Series Fon 49 821 570451 0 Fax 49 821 570451 25 www eps germany de info eps germany de 4 3 Calibration readjustment 51 4 3 1 Preface 51 4 3 2 Preparation 51 4 3 3 Calibration procedu...

Страница 5: ...n a separate document 1 1 4 Explanation of symbols Warning and safety notices as well as general notices in this document are shown in a box with a symbol as follows Symbol for a life threatening dang...

Страница 6: ...current of the device in Ampere Maximum voltage of the device in Volt Series 8 Series 8000 or 800 9 Series 9000 Type identification PS Power Supply usually programmable PSI Power Supply Intelligent a...

Страница 7: ...urns as well as damage to the equipment and to the source ESD regulations must be applied when plugging interface cards or modules into the relative slot Interface cards or modules may only be attache...

Страница 8: ...onsibilities for operation maintenance and cleaning of the equipment ensure that all employees who use the equipment have read and understood the manual Furthermore the users are to be regularly schoo...

Страница 9: ...elf due to a defect or because the adjusted OVP threshold was lower than the actual output voltage Critical The device and or the load could be damaged Signal OCP OverCurrent Shutdown of the DC output...

Страница 10: ...ay Accuracy 3 0 2 UNom 0 2 UNom 0 2 UNom 0 2 UNom 0 2 UNom Ripple 2 100 mVPP 5 2 mVRMS 293 mVPP 51 mVRMS 195 mVPP 33 mVRMS 293 mVPP 63 mVRMS 260 mVPP 40 mVRMS Remote sensing compensation Max 5 UNenn M...

Страница 11: ...led fans front inlet rear exhaust Ambient temperature 0 50 C Storage temperature 20 70 C Humidity 80 not condensing Standards EN 61010 EN 61326 Overvoltage category 2 Protection class 1 Pollution degr...

Страница 12: ...UNom 0 2 UNom 0 2 UNom Ripple 2 76 mVPP 4 2 mVRMS 234 mVPP 40 mVRMS 156 mVPP 26 mVRMS 234 mVPP 50 mVRMS 260 mVPP 40 mVRMS Remote sensing compensation Max 5 UNom Max 5 UNom Max 5 UNom Max 5 UNom Max 5...

Страница 13: ...ntrolled fans front inlet rear exhaust Ambient temperature 0 50 C Storage temperature 20 70 C Humidity 80 not condensing Standards EN 61010 EN 61326 Overvoltage category 2 Protection class 1 Pollution...

Страница 14: ...ies Fon 49 821 570451 0 Fax 49 821 570451 25 www eps germany de info eps germany de Figure 1 Front side Figure 2 Rear side 1 8 4 Views A Mains switch D Exhausts G AC input connector B Control panel E...

Страница 15: ...bH Alter Postweg 101 86159Augsburg Germany Fon 49 821 570451 0 Fax 49 821 570451 25 www eps germany de info eps germany de PS 9000 1U Series Figure 3 Left hand side view with DC cover Figure 4 Right h...

Страница 16: ...Page 16 EPS Stromversorgung GmbH Alter Postweg 101 86159Augsburg Germany PS 9000 1U Series Fon 49 821 570451 0 Fax 49 821 570451 25 www eps germany de info eps germany de Figure 5 Top view...

Страница 17: ...the setup menu Button Navigates through menus submenus and parameters direction up left or changes view mode Button Navigates through menus submenus and parameters direction down right or changes view...

Страница 18: ...addition the devices offer as standard the possibility for parallel connection in Share bus operation for constant current sharing Operating in this way allows up to 10 units to be combined to a sing...

Страница 19: ...doing so the digit to adjust can be selected by pushing the corresponding rotary knob in order to move the cursor The left hand rotary knob is always assigned to the DC output voltage and related para...

Страница 20: ...ds on the device model The values have 4 or 5 digits while actual and set values related to the same physical unit always have the same number of digits Adjustment resolution and number of digits of s...

Страница 21: ...ess via a freely selectable port except 80 and other reserved ports The standard port for this device is 5025 default IP is 192 168 0 2 Via TCP IP and this port communication to the device can be esta...

Страница 22: ...transport with or without packaging or before commissioning the equipment should be visually inspected for damage and completeness using the delivery note and or parts list see section 1 9 3 Scope of...

Страница 23: ...o AC supply The device can be connected to any wall socket or multi socket outlet as long as those feature a safety contact PE and are capable for 16 A When connecting the device to a multi socket out...

Страница 24: ...mbient temperature For cables up to 1 5 m and average ambient temperature up to 50 C we recommend up to 10 A 0 75 mm AWG18 up to 15 A 1 5 mm AWG14 up to 30 A 4 mm AWG10 up to 40 A 6 mm AWG8 up to 60 A...

Страница 25: ...nnect the remote sensing input Sense to the load The device recognizes the remote sensing mode automati cally and regulates the output voltage only in CV operation at the load rather than at its own D...

Страница 26: ...erating systems such as Windows 7 or 10 But it is strongly recommended to use and install the included driver installer on USB stick to gain maximum compatibility of the device to our softwares 2 3 10...

Страница 27: ...te in a browser by entering the default IP http 192 168 0 2 or the default host name http Client only possible if there is a running DNS in the network into the URL box 3 After the website has been co...

Страница 28: ...on the adjusted value unless the output current or the output power according to P UOUT IOUT reaches the adjusted current or power limit In both cases the device will automatically change to constant...

Страница 29: ...achieved if the maximum power value limits the output current according to I P U The adjustable set value of current as indicated in the display is always only an upper limit While the DC output is sw...

Страница 30: ...wn the unit until it can automatically switch on again to continue operation 3 3 3 Overvoltage An overvoltage alarm OVP will switch off the DC output and can occur if the power supply itself as a volt...

Страница 31: ...either on or off All set values are always saved and restored 3 4 2 Switching off the device On switch off the last output condition and the most recent set values are saved Furthermore a PF alarm po...

Страница 32: ...____W Limits U min ____V U max ____V I min ____A I max ____A P max ____W General Calibration Reset Communication IP Settings 2 HMI Setup Language English Deutsch Display Language Brightness 1 10 HMI L...

Страница 33: ...ition will be restored to the condition prior to switch off DC output after PF alarm 6 Determines how the DC output shall react after a power fail PF alarm has occurred OFF DC output will be switched...

Страница 34: ...manent manual setting of the device s IP address in standard IP format Subnet mask Only available with setting Get IP address Manual Default value 255 255 255 0 Permanent manual setting of the subnet...

Страница 35: ...its apply to every kind setting a value That also includes remote control via analog or digital interface In remote control the global range of 0 100 digital resp 0 5 V 0 10 V remains only narrowed by...

Страница 36: ...ing on your setting the main display will change after leaving the setup menu and the right hand rotary knob is then either assigned to set value of current or power 3 4 6 Manual adjustment of set val...

Страница 37: ...control panel being locked Switching the DC output on during manual operation or digital remote control can be disabled by pin REM SB of the built in analog interface For more information refer to 3...

Страница 38: ...lowing If remote control via the digital interface is active Remote then remote control is immediately terminated and must be reactivated at the PC once Local is no longer active If remote control is...

Страница 39: ...the interface Analog remote control of the device must be activated by switching pin REMOTE 5 first Only exception is pin REM SB which can be used independently since KE firmware version 2 03 Before...

Страница 40: ...0 5 V corre spond to 0 100 von PNom Accuracy 0 5 V range 0 4 Accuracy 0 10 V range 0 2 Input impedance Ri 40 k 100 k 9 VMON AO Actual voltage 0 10 V or 0 5 V corre spond to 0 100 von UNom Accuracy 0...

Страница 41: ...tput of the device on and off From KE firmware version 2 03 this is also available without remote control being active It is recommended that a low resistance contact such as a switch relay or transis...

Страница 42: ...d power Requires remote control to be activated Pin Remote LOW The set values VSEL and CSEL are generated from the reference voltage VREF using potentiometers for each Hence the power supply can selec...

Страница 43: ...control 1 Switch off the DC output by pulling pin REM SB to the level that corresponds to DC output off then switch it on again See section 3 5 4 7 Application examples for levels and logic How to ack...

Страница 44: ...ted without prior unlocking You can choose between a simple lock and a PIN lock which requires to enter the correct PIN every time someone wants to unlock the HMI How to lock the HMI 1 Switch off the...

Страница 45: ...rofile change can also be accompanied by a change in HMI language On calling up the menu page and selecting a profile the most important settings can be seen but not changed How to save the current va...

Страница 46: ...nit in the parallel operation is simply connected to the next unit using cables with cross section according to the maximum current and with short as possible length 3 9 1 2 Wiring the Share bus The S...

Страница 47: ...ies connection is only allowed with devices of the same kind and model i e power supply with power supply like for example PS 9080 100 1U with PS 9080 100 1U or similar models like PS PSI 9080 120 2U...

Страница 48: ...The maximum approved limits for the application should be set in the power supply This can be done via the interface The electronic load should preferably be in operating mode CV The load will then us...

Страница 49: ...age of 26 V at test start DC input s and DC output s of all units switched off In this combination of devices it is recommended to always switch on the DC output of the source first and then the DC in...

Страница 50: ...much detail as possible is attached if shipping destination is abroad the necessary customs papers are attached 4 2 1 Replacing a defect mains fuse The device is protected by one fusible T16 A 250 V 3...

Страница 51: ...itions are required A measurement device multimeter for voltage with a max error of half the PS s voltage error That measure ment device can also be used to measure the shunt voltage when readjusting...

Страница 52: ...urrent limit being loaded by the load or sink and start to measure the output current I mon Simply confirm here with 4 After this the device requests you to enter the output current which you are meas...

Страница 53: ...ut not least save the calibration data permanently confirming menu item Save exit with Leaving the calibration selection menu without saving via Save exit will discard calibration data and the procedu...

Страница 54: ......

Страница 55: ......

Страница 56: ......

Отзывы: