► How to configure the device alarms OVP, OCP and OPP
1.
Switch off the DC output and push button
to call the setup menu.
2.
In the menu navigate to “
Settings”
and push
. Then in the submenu navigate to “
Protection Settings
”
and push
again.
3.
Set the limits for the equipment alarm relevant to your application if the default value of 110% of nominal is
unsuitable.
4.
Accept the settings with
or discard them with
.
Those thresholds are reset to defaults when using the function “
Reset Device
” in setup menu.
► How to configure the alarm sound
1.
Switch off the DC output and push button
to call the setup menu.
2.
In the menu navigate to “
HMI Setup”
and push
. Then in the submenu navigate to “
Alarm Sound
”
and push
again.
3.
In the following screen set parameter “
Alarm Sound”
to either
OFF
or
ON
.
4.
Accept the settings with
or discard them with
.
3.7
Control panel (HMI) lock
In order to avoid the accidental alteration of a value during manual operation the rotary knobs or the key strip of
the control panel (HMI) can be locked so that no alteration will be accepted without prior unlocking.
►
How to lock the HMI
1.
Switch off the DC output and push button
to call the setup menu.
2.
In the menu navigate to “
HMI Setup”
and push
. Then in the submenu navigate to “
HMI Lock
” and
push
again.
3.
Make your selection for parameter “
HMI Lock
”. With selection “
Lock
all
” everything on the HMI is locked
and you can’t even switch on the DC output. In order to be able to do at least that, use “
ON/OFF possible
”.
4.
The lock is activated as soon as you confirm your selection with
. The device will automatically exit the
menu and jump back to normal display with status “
Locked
” now being indicated.
If an attempt is made to alter something whilst the HMI is locked, a requester appears in the display asking if the
lock should be disabled.
►
How to unlock the HMI
1.
Rotate any knob or push any button except ON/OFF.
2.
This request pop-up will appear:
.
3.
Unlock the HMI by pushing
within 5 seconds, otherwise the pop-up will disappear and the HMI re-
mains locked.