background image

Mini Environmental  

Quality Meter

850027

Instruction Manual

Содержание 850027

Страница 1: ...Mini Environmental Quality Meter 850027 Instruction Manual ...

Страница 2: ...ying recording or any information storage and retrieval system without the express permission from Sper Scientific INTRODUCTION For environmental testing anywhere Model 850027 combines 11 environmental test functions into a single compact unit Features include touch tone buttons min max and hold functions Comes ready to use with wrist strap instructions battery and soft carrying case MATERIALS SUP...

Страница 3: ...n off 6 LCD backlight on off 6 Mode selection 6 Unit selection 6 Special attention for the Humidity measurement 8 Air flow measurement 9 Barometric measurement 10 Altitude measurement 11 Optional Pt 1000 probe 13 Hold Function 13 REC Record function 13 Auto power off disable 14 6 BATTERY REPLACEMENT 14 7 SPECIFICATIONS 15 8 WARRANTY 20 ...

Страница 4: ...rovides high accuracy at high and low air velocity High precision humidity sensor with fast response time Barometric sensor for precise atmosphere and altitude measurement Built in microprocessor circuit assures excellent performance and accuracy Optional Pt 1000 Temp probe Concise and compact buttons arrangement for easy operation Maximum and minimum memory with recall Hold function F C selection...

Страница 5: ...dity Temp sensor 3 8 Battery Compartment Cover 3 9 Buttons operation label 3 10 Anemometer Temp sensor 3 7 4 1 8 2 3 11 10 5 1 HOLD button 2 Button Power button 3 REC button 4 LCD display 5 Wristlet 6 Light sensor 7 Anemometer vane 8 Humidity Temperature sensor 8 Barometer sensor 10 Battery compartment cover 11 Buttons operation label 12 Pt 1000 ohm probe socket 6 12 9 ...

Страница 6: ...klight on off With the meter on press once The LCD backlight will light for 5 seconds then shut off automatically Mode selection This meter offers 11 selectable modes a Anemometer Air velocity Temp b Air flow CMM CFM c Wind Chill d Humidity Temp e Dew point Temp f Wet bulb Temp g Heat index h Light i Barometric pressure j Altitude k Pt 1000 Temp optional ...

Страница 7: ...ex LIgHt Light bAr Barometric pressure HigH Altitude Pt Pt 1000 Temp optional When the display shows the desired mode release HOLD and the meter will set this mode as the default Anemometer Air Velocity Temp Measurement Unit Selection REC button Enter button 1 With the power on press REC for 3 seconds the display will show Unit Release REC then press to scroll through the available scales After th...

Страница 8: ...t and HEAt are the selected mode you may only change the temperature scale setting F or C The selection scales for all modes are Measurement Scales Air Velocity m s Km h mph knot FPM Temp Air velocity F C Air flow CMM CFM Wind chill F C Temp Humidity F C Dew point F C Wet bulb Temp F C Heat index F C Light Lux FC Barometric Pressure hPa mmHG inHG Altitude m ft Pt 1000 Temp F C ...

Страница 9: ...se HOLD and to adjust the air flow dimension value When the desired dimension value is set press REC to save as the default button button HOLD button button REC button Enter button Note For the most accurate reading for the humidity Temp Dew point Temp Wet bulb Temp Heat index measurement do not touch or block the humidity sensor at any time with your hand Light measurement For light measurement h...

Страница 10: ... the measurement location changes in response to two things changes in altitude and changes in atmosphere 2 Sea level barometric pressure value measurement Press HOLD once the Display will show the Hold indicator then press REC continuously until the bottom left of the display shows m or ft m meter ft feet Use HOLD and to adjust the location altitude value When the location altitude value is set p...

Страница 11: ...surement Note The higher the location altitude in comparison to sea level the lower the barometric pressure To measure your altitude value precisely a Method 1 Set the altitude value if your start location is known b Method 2 Reset the sea level barometric pressure value first Method 1 Power on the meter and under the altitude function press HOLD once the display will show the Hold indicator Press...

Страница 12: ...the exact altitude for a given address www earth google com You can also get the reference altitude value from the reading of a GPS system Method 2 Power on the meter and under the altitude function press HOLD once the display will show the Hold indicator Press REC continuously until the bottom left of display shows HPA indicator flashing Release REC Use HOLD and the to adjust the current sea leve...

Страница 13: ...to Pt 1000 Temp refer to page 6 now the meter is ready for Pt 1000 Temp measurement Hold Function Pressing HOLD will freeze the current reading on the display The Hold symbol will be displayed at the top of the display window To release the Hold function press HOLD again the Hold indicator will disappear and the current reading will be displayed REC Record function The REC Record function will rec...

Страница 14: ...tion press REC button for 2 seconds Auto power off disable In order to prolong the battery life this instrument has an Auto Power Off function the meter will turn off if no buttons are pressed for approximately 10 minutes To disable the Auto Power Off function press REC and enter the record function page 13 The Auto power off function will be disabled until the record function is exited REPLACE BA...

Страница 15: ...ll 9 Heat index 10 Altitude 11 Pt 1000 Temp opt Operating Humidity Max 80 RH Operating Temp 32 to 122 F 0 to 50 C Over Input Display Power Supply CR 2032 DC 3V battery Power Consumption Approx DC 5 mA Weight 2 3 oz 68g battery included Dim HWD 4 x 1 x 1 120 x 44 x 23 mm Standard Accessories Instruction Manual battery soft case Optional Accessories 850027P Pt 1000Temp probe ...

Страница 16: ...0 1 km h mph 0 9 to 44 7 mph 0 1 mph knots 0 8 to 38 8 knots 0 1 knots F 32 to 122 F 0 1 F 2 5 F C 0 to 50 C 0 1 C 1 2 C VELOCITY DEFINITIONS ft min feet per minute m s meters per second km h kilometers per hour mph miles per hour knots nautical miles per hour Air Flow Range Resolution CMM 0 024 to 36000 CMM 0 001 0 01 0 1 1 CMM CFM 0 847 to 1271300 CFM 0 001 0 01 0 1 1 10 x10 100 x100 CFM ...

Страница 17: ...uracy RH 10 to 95 RH 0 1 RH 70 RH 4 RH 70 RH 4 RDG 1 2 RH F 32 to 122 F 0 1 F 2 5 F C 0 to 50 C 0 1 C 1 2 C Wind chill Range Resolution Accuracy F 15 to 112 F 0 1 F 3 6 F C 9 to 44 C 0 1 C 2 0 C Wet bulb Temperature Range Resolution Remark F 22 to 120 F 0 1 F Calculated from the humidity Temp value C 5 to 49 0 C 0 1 C Wind chill value is in effect only when the Temp value 15 C and Air velocity val...

Страница 18: ... 860 FC 1 FC ELECTRICAL SPECIFICATIONS 74 9 F 23 5 C Barometric Pressure Barometer Range Resolution Accuracy hPa 10 0 to 999 9 hPa 0 1 hpa 1 5 hPa 1000 to 1100 hPa 1 hpa 2 hPa mmHg 7 5 to 825 0 mmHg 0 1 mmHg 1 2 mmHg inHg 0 29 to 32 48 inHg 0 01 inHg 0 05 inHg Alititude Range Resolution Accuracy m 2000 to 9000 m 1 m 15 m ft 6000 to 30000 ft 1 ft 50 ft ...

Страница 19: ...th prolonged exposure and activity Continuing activity could result in heat cramps 90 to 105 F 32 to 41 C Extreme caution Heat cramps and heat exhaustion are possible Continuing activity could result in heat stroke 105 to 130 F 41 to 54 C Danger Heat cramps and heat exhaustion are likely heat stroke is probable with continued activity 130 F 54 C Extreme danger Heat stroke is imminent Exposure to f...

Страница 20: ...bes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will void the warranty To obtain warranty service shipthe unit postage prepaid to SPER SCIENTIFIC LTD 8281 E Evans Rd Suite 103 Scottsdale AZ 85260 The defective unit must be accompanied by a description of the problem and your return address Register...

Отзывы: