ePOOL™  TROUBLe SHOOTING GUIDe 

(mODeL #4819, veRSION 2)

ImPORTANT:

 

Prior to troubleshooting a receiver message, recycle the power FIRST.  

To recycle the power, unplug the receiver, wait 10 seconds and then plug the receiv-

er back in.  If you still have the same message, check for other causes listed below.   

RECEIVER  

MESSAGE

POSSIBLE 

CAUSES

SOLUTIONS

Communication Error

Receiver is NOT within 
a 100 foot direct line 
of sight of the floating 
unit.  

Unplug the receiver.  Move unit to within a 100 foot 
direct line of sight with the receiver.  See “For Best 
Results” Section.  Plug the receiver back in.

Floating unit is under 
a pool cover.

Unplug the receiver. Uncover the floating unit.  Plug 
the receiver back in. 

Floating unit is next to 
the pool edge/coping.

Unplug the receiver.  Move the unit to a more central-
ized location in your pool.  Plug the receiver back in.

If you are still receiv-
ing this message.

Contact GAME.

pH Sensor Fault: 

pH is above or below 
measurement range

pH reading is 0.0.

Sensor glass is broken and will need replacing.  

Sensor glass may be 
broken and will need 
replacing.  

Remove bottom cap as instructed on page 16 of your 
Owner’s Manual.  Check to see if the glass sensor is 
broken.  If it is, contact GAME.  

Your pool water is out 
of balance.  

Take a test sample of pool water to confirm reading.  If 
necessary, add the appropriate chemicals to bring your 
pool back into this range.  

Then unplug the receiver, wait 10 seconds and plug the 
receiver back in. 

If you are still receiv-
ing this message.

Contact GAME.