background image

pg. 2

ECA-70MIXAMP-1-60 Installation Manual

Important Safety Instructions

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

The lightning flash with arrowhead symbol, within an equilateral triangle, 
is intended to alert the user to the presence of un-insulated dangerous 
voltage within the product’s enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the 
user to the presence of important operating and maintenance (servicing) 
instructions in the literature accompanying the appliance.

CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER 
SERVICING TO QUALIFIED SERVICE PERSONNEL.

1.     Read and follow all instructions and warnings in this manual. Keep for future reference.
2.  Do not use this apparatus near water.
3.  Clean only with a dry cloth.
4.  Do not block any ventilation openings. Install according to manufacturer’s instructions.
5.  Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce 

heat.

6.  Do not override the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades - one wider than the other. 

A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the 
provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

7.  Protect the power cord from being walked on or pinched particularly at plug, convenience receptacles, and the point where it exits 

from the apparatus.

8.  Only use attachments/accessories specified by the manufacturer.
9.  Use only with a cart, stand, tripod, bracket or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use 

caution when moving the cart/apparatus combination to avoid injury from tip-over.

10.  Unplug this apparatus during lightning storms or when unused for long periods of time.
11.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 

when the power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has 
been exposed to rain or moisture, does not operate normally, or has been dropped.

12.  DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR SPLASHING AND ENSURE THAT NO OBJECTS FILLED WITH LIQUIDS, 

SUCH AS VASES, ARE PLACED ON THE EQUIPMENT.

13.  TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC MAINS, DISCONNECT THE POWER SUPPLY CORD PLUG 

FROM THE AC RECEPTACLE.

14.  THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE.

WARNING:

CAUTION

CAUTION: TO REDUCE THE RISK OF 

ELECTRICAL SHOCK.

DO NOT REMOVE COVER. NO USER 

SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED 
SERVICE PERSONNEL.

Содержание ECA-70MIXAMP-1-60

Страница 1: ...0 0 0 0 0 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 9 9 9 9 9 10 10 10 10 10 12 12 12 12 0 0 0 1 2 3 4 5 6 7 8 9 10 ECA 70MIXAMP 1 60 POWER ON OFF MIC 1 MIC 1 MI...

Страница 2: ...a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 7...

Страница 3: ...ne l assaut ou si inutilis pendant de longues p riodes 11 R f rez vous tous qui entretiennent au personnel de service qualifi L entretien est exig quand l appareil a t endommag de quelque fa on comme...

Страница 4: ...s Overview Features Front Panel Rear Panel Installation Positioning the Amplifier Rack Mounting Standard Connections Microphone Input Pinouts Advanced Connections Cascading Amplifiers Specifications T...

Страница 5: ...for your commercial audio needs 60 Watts RMS 1 Channel Low Frequency filter protection Power level meter Set screw type output terminals for secure easy connections 2 Auxiliary Source Inputs Mixed pre...

Страница 6: ...D will light red and output will be disabled LED off indicates normal operation If problem recurs see Troubleshooting Section Note When amp is turned on and off the Protection LED will turn on for a m...

Страница 7: ...gnal from balanced inputs 2 and 3 5 IEC Power Cord Detachable power cord 6 AC Fuse Replaceable main power fuse 7 Speaker Output Connector Spade terminal connections for 70V 100V or 4 16 speakers atten...

Страница 8: ...sides of the unit Do not place the unit on carpeting or any similar material Do not install the unit near a source of heat or in an extremely humid or wet location If your installation lacks good air...

Страница 9: ...AMP 1 60 PLAY Blu ray DVD Player PC Audio Standard Connections Advanced Connections While the ECA 70MIXAMP 1 60 can be used in a variety of configurations the diagram below shows the basic application...

Страница 10: ...iliary RCA Inputs 350mV 10k Unbalanced Line Level RCA Left Right EMC Input 775mV 10K Ohms unbalanced mono spade terminals Signal To Noise Ratio MIC 1 2 and 3 60dB AUX 1 and 2 73dB Frequency Response 5...

Страница 11: ...and ensure power outlet is providing the correct power and polarity for the amplifier TEMP LED is lit Amplifier is overheating Install per instructions in manual Positioning the Amplifier PROT LED is...

Страница 12: ...2013 Episode 131115 1028...

Отзывы: