OPERATION INFORMATION
Owner’s Manual
18
3.
Hold the hydrometer in a vertical position at eye level and note the reading where the electrolyte meets the
scale on the float.
4.
ρ
25
℃
=
ρ
t +0.0007
(
t-25)
ρ
25
℃
——
25
℃
electrolyte specific gravity
;
ρ
t
——
t
℃
electrolyte specific gravity
.
5. Test each cell and note the readings (corrected to 80° Fig. 30 Hydrometer F or 27° C). A variation of fifty
points between any two cell readings (example 1.250 -1.200) indicates a problem with the low reading cell(s).
As a battery ages the specific gravity of the electrolyte will decrease at full charge. This is not a reason to replace
the battery, providing all cells are within fifty points of each other.
Since the hydrometer test is in response to a vehicle exhibiting a performance problem, the vehicle should be
recharged and the test repeated. If the results indicate a weak cell, the battery or batteries should be removed and
replaced with a good battery of the same brand, type, and approximate age.
BATTERY MAINTENANCE
Our experience shows that the key to achieving optimum performance and long life is a solid battery
maintenance program using the simple procedures
outlined here.
Equipment:
We recommend the following equipment for use in battery care and maintenance:
Recommended Equipment:
◆
◆
Wrench
◆
Distilled Water
◆
Voltmeter
◆
Hydrometer
◆
Thermometer
◆
Post Cleaner
◆
Baking Soda
◆
Vaseline
◆
Goggles & Gloves
CAUTION
: Always wear protective clothing, gloves, and goggles
When handling batteries, electrolyte, and charging your battery.
Содержание E40FL