SAFETY INSTRUCTIONS

Read and understand this entire manual before attempting to assemble, operate, or install the LED Luminaire. If you 

have any questions regarding the product, please call Ephesus Customer Service at (800) 573-3600.
1.  All electrical work must conform to the National Electric Code (NEC) and all applicable local codes and ordinances.
2.  Only qualified personnel shall install and maintain the luminaires. Ephesus recommends that a licensed electrician 

install and maintain the luminaire. Verify the safety of existing power distribution system before beginning 

installation. Failure to follow Operating Instructions may lead to death, Severe Injury, or Property Damage.

WARNING

Turn off power before performing any electrical or control work. FAILURE TO FOLLOW THIS WARNING MAY LEAD 

TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.

DO NOT make or alter any open holes in the luminaire. Do not modify the luminaire.

WARNING

Follow all applicable safety procedures and use Personal Protective Equipment such as hardhats, safety glasses, 

reflective vests, electrical safety gloves, fall protection equipment and safety toe boots during the installation, 

operation, and maintenance of the luminaire. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO DEATH, 

SEVERE INJURY, OR PROPERTY DAMAGE.

WARNING

Risk of eye injury! Eye protection is required at all times during the installation, operation, and maintenance of 

the luminaire. The high intensity light produced by the luminaire can cause severe damage to the eye if viewed 

directly at close range.  Avoid being in front of a luminaire that is on or wear suitable light blocking protective 

eyewear such as welding goggles. The luminaire should be positioned so that prolonged staring into the 

luminaire at a distance closer than 10m is not expected

Store luminaires in a clean, dry place, protected from dirt, water, and sunlight.  See table for required storage and 

operating conditions:

Storage Temperature

Operating Temperature

Humidity

-40°C to +75°C (-40°F to 167°F)

-40°C to +55°C (-40°F to 131°F)

5% to 95% non-condensing

Storage and Operating Conditions

This manual applies to the following models:
All Field 750/550
Arena 750/650/550

Содержание All Field 550

Страница 1: ...ow all applicable safety procedures and use Personal Protective Equipment such as hardhats safety glasses reflective vests electrical safety gloves fall protection equipment and safety toe boots durin...

Страница 2: ...nt wrenches sized to fit mounting hardware Step 1 Mount the Luminaires 3 16 Hex driver or metric equivalent Step 3 Make Electrical Connections Torque wrench es rated from 35 to 75 in lbs 4 to 8 N m an...

Страница 3: ...ystem must be grounded If you are not sure if your power system is grounded DO NOT install the luminaire Contact a licensed electrician for information on proper grounding methods as required by the e...

Страница 4: ...e the fixture FAILURE TO FOLLOW THIS WARNING MAY LEAD TO LUMINAIRE INTERNAL DAMAGE AND FAILURE There are two different ways to mount the All Field fixture Standard and Inverted Standard mounting is wh...

Страница 5: ...g The luminaire hangs from underneath mounting structure WARNING When using inverted mounting flip the mounting bracket so that the luminaire stays upright NEVER install the luminaire upside down FAIL...

Страница 6: ...ation instructions rev 170117 Installation Instructions All Field LED Luminaire Figure 4 Inverted Mounting Locknut Washers Hex Bolt Mounting Structure Figure 3 Inverting the Mounting Bracket Mounting...

Страница 7: ...e from the catwalk 1 Label each fixture with Luminaire Number as indicated on schedules in the project Installation drawings 2 Labels shall be white background with black lettering Text shall be at le...

Страница 8: ...rip in the junction box cover 3 Strip outer jacket of incoming power cable back 3 7cm Connect the incoming power wires to the fixture power wires on right side of junction box Fixture power wire color...

Страница 9: ...e the incoming control line into the left side of the fixture junction box by removing the plug and providing and installing a or metric equivalent cord grip appropriately sized to hold the control wi...

Страница 10: ...Set the luminaire Orient by rotating the luminaire mounting bracket relative to the mounting structure Unless otherwise noted Orient values shown in Ephesus photometrics or project Installation Drawi...

Страница 11: ...rench driver WARNING NEVER use any power tools on the fixture while the power is on The vibration caused by power tools may damage the fixture FAILURE TO FOLLOW THIS WARNING MAY LEAD TO LUMINAIRE INTE...

Страница 12: ...tion drawings for aiming point coordinates Note N After targeting the aiming point with the laser turn off the laser to conserve battery life Hardware Torque Value Side Set screw 35 75 in lbs 4 to 8 N...

Страница 13: ...est practices website has grid layouts by sport http www ncaa com news ncaa article 2013 11 21 ncaa best lighting practices 3 Review the light measurements and compare the data to project requirements...

Страница 14: ...abrasive polycarbonate cleanser may be used periodically WARNING Do NOT use any abrasives such as car wax brass cleaners or other polishes or chemicals These may scratch remove or damage the protectiv...

Страница 15: ...15 EATON MN507001EN All Field Installation Manual rev 20170324 Installation Instructions All Field LED Luminaire...

Страница 16: ...das las marcas comerciales son propiedad de sus respectivos propietarios Product availability specifications and compliances are subject to change without notice La disponibilit du produit les sp cifi...

Отзывы: