CAUTION!
The thermostat must not be left unsupervised
when open. (Prevent non specialists and especially
children from gaining access to it.)
Only qualified electricians or authorised service
staff are permitted to open the thermostat.
If the thermostat is used in a way not specified by
the manufacturer, its safety may be impaired.
Operating Instructions
Page 1 of 4
RFRP-OT Room Thermostat
Wireless
4. Installation
1. Factory default settings
How your programmable thermostat works
6. LCD Symbol / button description
5. Frost protection
2. Specifications
Temperature indicator:
°C
Switching differential:
0.4°C
In built frost protection:
5°C - Not adjustable
Clock:
24 hours
Keypad lock:
Off
Operating mode:
5/2 day
5°C
Operating mode
Current program
Day / Month
Day of the week
Temperature
Battery low symbol
Wireless symbol
Heating on symbol
Keypad lock symbol
Current Time
(Boost to time)
3. Mounting
Contents
1. Factory default settings
2. Specifications
3. Mounting
4. Installation
5. Frost protection
6. LCD symbol / buttons description
7. Resetting the thermostat
8. Keypad lock and unlock
9. Setting the date, time and operating mode
10. Factory program settings
11. Adjusting the program settings for 5/2d
12. Copy Function
13. Temporary override
14. Permanent override
15. Boost function
16. Holiday function
17. To connect the RFRP-OT thermostat to an RF1A-OT receiver
18. To disconnect the RFRP-OT thermostat from an RF1A-OT receiver
19. Backlight mode selection
20. Battery low warning
21. Replacing the batteries
22. Installer Menu (without OpenTherm® connected)
Prior to setting the thermostat, it is neccessary to
complete all required settings described in this section.
6.1 LCD Symbol description
EPH Controls Ireland
[email protected] www.ephcontrols.com
EPH Controls UK
[email protected] www.ephcontrols.co.uk
Boiler
Plus
RFRP-OT Room Thermostat
Wireless
20190627_RFRP-OT_OpIns_JW
Important: Keep this document
Power supply:
2 x AA Alkaline Battery
Power consumption:
2 mW
Battery replacement:
Once a year
Temp. control range:
5 ... 35°C
Ambient temperature:
0 ... 45°C
Dimensions:
130 x 99 x 25mm
Temperature sensor:
NTC 100K Ohm @ 25°C
Temperature indication:
˚C
Switching differential:
0.4˚C
Frost protection:
Only operational in OFF mode
Pollution degree:
Pollution degree 2
The mounting height should be 1.5 metres above the floor level.
The thermostat should be wall mounted in the room where the heating is to
be controlled.
The place of installation should be chosen so that the sensor can measure the
room temperature as accurately as possible.
Choose the mounting location to prevent direct exposure to sunlight or other
heating / cooling sources when mounted.
The unit can be fitted to:
1. Directly on walls.
2. Table mounting with stand provided.
When the thermostat is in the AUTO mode, it will operate according to the
times and temperatures that have been programmed. The user can select
from 6 different programs per day - each with a time and a temperature.
There is no OFF time, only a higher and a lower temperature.
If the user wants the thermostat to be OFF at a certain time, set the
temperature for this time to be low. The thermostat will turn ON if the room
temperature is lower than the setpoint for the current period.
Example: If P1 is set to be 21˚C at 6am, and if P2 is set to be 10˚C at 8am, the
thermostat will look for the temperature to be 21˚C between 6am and 8am.
Frost protection is built into this thermostat.
It is pre fixed at 5°C and is not adjustable.
It will only be activated when the thermostat is in the OFF mode and the
room temperature falls below 5°C.
Lower the flap at the front of the thermostat.
There is a battery compartment located below the buttons.
Apply downward pressure to remove the cover.
Insert the 2 x AA batteries and the thermostat will turn on.
Close the battery compartment.