background image

CAUTION!

             

Before commencing any work on the electrical 

mains. None of the 230V connections must  be live until the 

installation has been completed and the housing is closed. 

permitted to open the terminal box.
There are parts that carry mains voltage behind the cover. The 

terminal box must not be left unsupervised when open. 

(Prevent non specialists and especially children from gaining 

access to it.)
Ensure that this wireless enabled receiver is installed 1 metre 

from any metalic object, television, radio or wireless internet 

transmitter.

Operating Instructions

Page 1 of 2

RF1A-OT - Wireless Receiver 

with RFRP-HW-OT

RF1A-OT - Wireless Receiver 

with RFRP-HW-OT

3.  Installation

1.  

2.  Mounting

     

 Contents 

2.   Mounting

3.   Installation

4.   Button / LED description

5.   Resetting the RF1A-OT receiver

6.   To connect the RFRP-HW-OT thermostat to an 

 

RF1A-OT receiver

7.  To disconnect the RFRP-HW-OT thermostat from an 

 

RF1A-OT receiver

Prior to operation, it is neccessary to complete all 

required settings described in this section.

4.  Button / LED description

Important: Keep this document

The RF1A-OT receiver should be wall mounted in an area within 20 
metres distance of the wireless thermostat.
It is important that the receiver is mounted more than 1 metre away from 

The receiver should also be installed at least 1metre from any electronic 
devices such as radio, TV, microwave or wireless network adaptor.

   2. Surface mounting boxes

*   If mains voltage output is required,  terminals L & 2 must be electrically linked. 
 

Important:

 Do not connect Mains Voltage to OpenTherm® terminals.

OFF

ON

3

2

1

L

N

L

MAINS SUPPLY

N

COM

Power Supply: 200 - 240Vac 
 

50-60Hz

Contact Rating: 250 Vac 10(3)A 
Ambient Temp: 0~45°C
Automatic Action: Type 1.C.Q

Class II appliance
Pollution degree:  Pollution degree2
Rated Impulse Voltage: Resistance to 
voltage surge 2500V; as per EN 60730
IP Rating: IP20

Internal wiring diagram 

for RF1A-OT

Slacken the fastening screw on the bottom of the receiver with a philips 
screwdriver.
The receiver is hinged and can be opened 180 degrees. Mount the unit as 
described in section 2. Wire the unit as described in section 1. Close the 
receiver and tighten the fastening screw.

System ON 

(Green LED) 

Manual override

Connect button

Wireless connect

indicator (Red LED)

Reset button

Manual override:

 This button will manually override the system.

LED description:

Wireless connect: 

Once voltage has been applied this button may be 

pressed to initialise the pairing process with the wireless thermostat. Once 

O T

O T

RF1A-OT On 

OT Connection Normal Operation

communicating via RF

ON

Green LED

Red LED

Green LED

Red LED

Green LED

Red LED

Green LED

Red LED

RF1A-OT On 

RF1A-OT On 

OT Communication Error

RF Communication Error

RF Communication Error

OT Communication Error

Normal Operation RF1A On

OFF or ON

OFF or ON

Constant Flash

Constant Flash

ON

ON or Flashing

OFF

OFF or Flashing

Summary

communicating via RF

OFF

ON

OFF

Constant Flash

Constant Flash

Constant Flash

Constant Flash

OFF

ON

20221005_RF1A_OT_RFRP-HW-OT_Opins_PK

EPH Controls Ireland

[email protected]    www.ephcontrols.com

EPH Controls UK

[email protected]    www.ephcontrols.co.uk