background image

Page 1

B1PF Actuator

3 Port Motorised Valve Actuator

Important: Keep this document

The B1PF range of actuators c/w auxiliary switch are specifically 

designed for use in domestic applications only. 

They are not designed for use in commercial or industrial 

applications such as schools, nursing homes or hotels where large 

commercial pump sets are fitted.

Warranty will be void If a valve is fitted in any application other 

than domestic.

Please note we have a full range of commercial and industrial valves 

to suit every application.

CAUTION!  

Installation and connection 

should only be carried out by a qualified person 

and in accordance with wiring regulations. 

 

ƒ

Do not open the products. There are no serviceable 

or adjustable parts inside. The system must be fused 

to no more than 3 Amps.

 

ƒ

Isolate mains supply before installation commences. 

 

ƒ

Isolate mains supply before attaching cable to 

actuator. 

 

ƒ

Isolate mains supply before detaching cable from 

actuator.

 

ƒ

If this equipment is installed or used in a way not 

specified by the manufacturer, its safety may be 

impaired.

TECHNICAL SPECIFICATION

ACTUATOR

MANUFACTURER

MODEL

SIZE & TYPE

MAX. CLOSE OFF PRESSURE

B1PF

replacement 

for

EPH

B322P(F)

22mm Compression

1.0 Bar

EPH

B328P(F)

28mm Compression

0.6 Bar

Honeywell

V4073A

22mm Compression

1.0 Bar

Honeywell

V4044C

28mm Compression

0.6 Bar

Horstmann

2322

22mm Compression

1.0 Bar

ACTUATOR

Motor supply voltage

230V

Impedance protected motor

Rated impulse voltage

2500V

Max. ambient temperature 

50˚C

Power consumption

5W

Protection rating

IP20

LEAD SUPPLIED

1.2 metre cable. Earth Connection required.

ACTUATOR OPERATION

230V Power to open - Spring return to close.
This is not a fail safe, a no fail or a safety product.
This control is designated Type 1. AA. C in accordance with EN60730.
Type of action is multi position. Type of movement is rotary.

MANUAL OVERRIDE

Valve may be manually opened for filling or draining the system.
In normal operation, the lever must be in the Auto position

If the mains power is disconnected, the valve will automatically spring 

return to the closed position (Port A)

Содержание DETACH PRO B1PF

Страница 1: ...from actuator If this equipment is installed or used in a way not specified by the manufacturer its safety may be impaired TECHNICAL SPECIFICATION ACTUATOR MANUFACTURER MODEL SIZE TYPE MAX CLOSE OFF PRESSURE B1PF replacement for EPH B322P F 22mm Compression 1 0 Bar EPH B328P F 28mm Compression 0 6 Bar Honeywell V4073A 22mm Compression 1 0 Bar Honeywell V4044C 28mm Compression 0 6 Bar Horstmann 232...

Страница 2: ...the actuator cover Remove the two screws that fix the base to the valve body Remove the base of the actuator 4 Fitting of actuator to the valve body Before fitting the actuator please ensure that the maual override lever is in the raised manual position and the fixing screw is loosened The actuator is mounted by aligning the 4mm flat spindle on the valve body to the identically sized slot on the a...

Страница 3: ...ammer and set the room thermostat to the maximum Port A should open on the valve The boiler should fire and the pump should run The pipe connected to Port A should get hot 9 For Hot Water and Central Heating Switch both the Hot Water and the Central Heating ON at the programmer Set both the room thermostat and the cylinder thermostat to the maximum The valve should go to the mid position with both...

Страница 4: ...vic Amenity site for free or returned to your retailer for free when you are buying a replacement Inappropriate waste handling could lead to negative effects on the environment and human health With your cooperation you contribute to the correct disposal reuse recycling and recovery of the components of this product and the protection of the environment EPH Controls UK T 01933 626 396 sales ephcon...

Отзывы: