Nor (Normal Mode)
When the thermostat is in Normal mode, the thermostat will try to
reach the target temperature after the program changes.
Example: Program 1 on the thermostat is 21°C for 06:30am and the
room temperature is 18°C. The thermostat will start the heating at
06:30am and the room temperature will start to increase then.
PO 1 Operating Mode
(Normal / Optimum Start / TPI)
OS (Optimum Start Mode)
Boiler
Plus
When the thermostat is in Optimum Start mode, the thermostat will try
to reach the target temperature by the start time of the next switching
time. This is done by setting the Ti (time interval) on the thermostat in
this menu to 10, 15, 20, 25 or 30. This will allow the thermostat 10, 15,
20, 25 or 30 minutes to increase the room temperature by 1°C.
Ti can be set when OS is selected in the installer menu.