background image

 

MPPT Solar Charge Controller

 

 

User Manual

 

Models: 

XTRA1206N/XTRA2206N 

XTRA1210N/XTRA2210N 

XTRA3210N/XTRA4210N

 

XTRA3215N/XTRA4215N 

XTRA3415N/XTRA4415N

 

 

Содержание XTRA1206N

Страница 1: ...MPPT Solar Charge Controller User Manual Models XTRA1206N XTRA2206N XTRA1210N XTRA2210N XTRA3210N XTRA4210N XTRA3215N XTRA4215N XTRA3415N XTRA4415N...

Страница 2: ...eable components inside the controller DO NOT disassemble or attempt to repair the controller Mount the controller indoors Avoid exposure the components and do not allow water to enter the controller...

Страница 3: ...re Size 9 2 4 Mounting 11 3 Display units 14 3 1 Basic Display unit XDB1 14 3 2 Standard Display unit XDS1 15 3 3 Adanced Display unit XDS2 19 4 Parameters Setting 25 4 1 Battery parameters 25 4 1 1 S...

Страница 4: ...5 2 Troubleshooting 37 5 3 Maintenance 39 6 Technical Specifications 40 Annex I Conversion Efficiency Curves 44...

Страница 5: ...controller owns self adaptive three stage charging mode based on digital control circuit which can effectively prolong the lifespan of battery and significantly improve the system performance It also...

Страница 6: ...ture value Multiple load work modes Comprehensive electronic protection Isolated RS485 with 5V 200mA protected output for no power devices with Modbus protocol Support monitoring and setting the param...

Страница 7: ...XDB1 XDS1 XDS2 Product Series Charge discharge current 1 10A 2 20A 3 30A 4 40A System Voltage 1 12VDC 2 12 24VDC Max PV open circuit voltage 10 100V 15 150V Common Negative System 1 4 Product Classif...

Страница 8: ...A N XDS2 LED Indicators PV battery load working status Buttons View or set the parameters or clear the error information LCD PV display voltage current generated energy power Battery display voltage c...

Страница 9: ...rounding materials or even cause fire Ensure tight connections and use cable clamps to secure cables and prevent them from swaying in mobile applications The controller can work with lead acid battery...

Страница 10: ...ditions STC Standard Test Condition Irradiance 1000W m2 Module Temperature 25 Air Mass1 5 XTRA1210 2210 3210 4210N System voltage 36 cell Voc 23V 48 cell Voc 31V 54 cell Voc 34V 60 cell Voc 38V Max Be...

Страница 11: ...arameter values are calculated under standard test conditions STC Standard Test Condition Irradiance 1000W m2 Module Temperature 25 Air Mass1 5 2 Maximum PV array power The MPPT controller has the fun...

Страница 12: ...onmental temperature the controller may be damaged According to Peak Sun Hours diagram if the power of PV array exceeds the rated charging power of controller then the charging time as per the rated p...

Страница 13: ...ds must conform to all national and local electrical code requirements PV Wire Size Since PV array output can vary due to the PV module size connection method or sunlight angle the minimum wire size c...

Страница 14: ...below Model Rated charge current Rated discharge current Battery wire size Load wire size XTRA1206N XTRA1210N 10A 10A 4mm2 12AWG 4mm2 12AWG XTRA2206N XTRA2210N 20A 20A 6mm2 10AWG 6mm2 10AWG XTRA3210N...

Страница 15: ...ow for proper air flow Ventilation is highly recommended if mounted in an enclosure Installation Procedure Figure 2 1 Mounting Step 1 Determination of Installation Location and Heat dissipation Space...

Страница 16: ...xternal surge arrester If an inverter is to be connected to the system connect the inverter directly to the battery not to the load side of the controller Step 3 Grounding XTRA N series is a common ne...

Страница 17: ...ture is 25 C without temperature compensation Connect the accessories for RS485 communication Refer to chaper4 Control Parameters Setting Step 5 Powered on the controller Closing the battery fuse will...

Страница 18: ...ver voltage Green On Solid Normal Green Slowly Flashing 1Hz Full Green Fast Flashing 4Hz Over voltage Orange On Solid Under voltage Red On Solid Over discharged Red Slowly Flashing 1Hz Battery Overhea...

Страница 19: ...ly flashing 25 50 Indicators on solid 50 BCL 75 Green 100 Indicator slowly flashing 25 50 75 Indicators on solid 75 BCL 100 Green 25 50 75 100 Indicators on solid 100 Indicator is OFF Indicator is on...

Страница 20: ...ON Red OFF Load OFF 2 Button Mode Note Load ON OFF In load manual mode it can turn the load On Off via the button Clear Fault Press the button Browsing Mode Press the button Setting Mode Press the but...

Страница 21: ...arging Battery Voltage Current Temperature Battery Type Load Load ON Load OFF Current Consumed energy Load mode 2 Browse interface Press the button to cycle display the following interfaces 3 Load par...

Страница 22: ...he button and hold 5s under the PV generated energy interface and the value will be flashing Step 2 Press the button to clear the generated energy Switch the battery temperature unit Press the button...

Страница 23: ...e is flashing Step3 Press the button to confirm the battery type CAUTION Please refer to chapter 4 1 for the battery parameters setting when the battery type is User Load working mode Operation Step1...

Страница 24: ...Load ON Yellow OFF Load OFF PV BATTLED fast flashing Controller Overheating System voltage error When a lead acid battery is used the controller doesn t have the low temperature protection When a lit...

Страница 25: ...ton Press the button Exit the setting interface 3 Display Icon Information Icon Information Icon Information Day Not charging Not discharging Night Charging Discharging 1 PV parameters Display Voltage...

Страница 26: ...Battery type Note If the controller supports 48V system voltage the battery type will display LiFePO4 F15 F16 and Li NiCoMn O2 N13 N14 Operation Step 1 Press the button to enter the setting interface...

Страница 27: ...tep 2 Press the button and hold 5s for the battery type interface Step 3 Press the button for the battery capacity interface Step 4 Press the or button to set the battery capacity Step 5 Press the but...

Страница 28: ...button and hold 5s for the LCD cycle time interface Step 3 Press the or button to set the LCD cycle time Step 4 Press the button to confirm the parameters 5 Local load working mode Operation Step 1 Pr...

Страница 29: ...O2 N13 N14 4 1 2 Local setting WARNING When the default battery type is selected the battery voltage parameters cannot be modified To change these parameters select the USE type Step1 Enter the USE ba...

Страница 30: ...button to confirm and enter the next parameter BCV 14 4V 9 17V 5 Press the button again to display the current voltage value 6 Press the button to modify the parameter short press to increase 0 1V lo...

Страница 31: ...y parameters Sealed Gel Flooded User LiFePO4 User Li NiCoMn O2 User Over voltage disconnect voltage BCV 1 4V voltage level BCV 0 3V voltage level BCV 0 3V voltage level Charging limit voltage BCV 0 6V...

Страница 32: ...Bluetooth module by Bluetooth signal When selecting the battery type as USE set the voltage parameters by the APP Refer to the cloud APP manual for details 3 Controller parameters Battery voltage para...

Страница 33: ...rging Limit Voltage Equalize Charging Voltage Boost Charging Voltage Float Charging Voltage Boost Reconnect Charging Voltage B Over Voltage Disconnect Voltage Over Voltage Reconnect Voltage C Low Volt...

Страница 34: ...x2 for LFP8S and x4 for LFP15S LFP16S Battery type Battery parameters LCNM LCNM3S LCNM6S LCNM7S LCNM13S LCNM14S User Over voltage disconnect voltage 12 8 V 25 6 V 29 8 V 55 4V 59 7V 9 17V Charging li...

Страница 35: ...ltage Reconnect Voltage Charging Limit Voltage Equalize Charging Voltage Boost Charging Voltage Float Charging Voltage Boost Reconnect Charging Voltage C Low Voltage Reconnect Voltage Low Voltage Disc...

Страница 36: ...ss the button to confirm the parameters 3 Load working mode 1 Timer 1 2 Timer 2 100 Light ON OFF 2 n Disabled 101 Load will be on for 1 hour after sunset 201 Load will be on for 1 hour before sunrise...

Страница 37: ...n 4 2 2 RS485 communication setting 1 Load working mode Manual Control default Control ON OFF of the load via the button or remote commands e g APP or PC software Light ON OFF Light ON Timer Time Cont...

Страница 38: ...oud platform manual for detail 2 APP software setting Connect the controller to the WIFI module through a standard network cable or connect to the Bluetooth module by Bluetooth signal Set the load mod...

Страница 39: ...fter the polarity is corrected CAUTION When the PV array is connected reversely to the controller and the PV array s actual operating power is greater than 1 5 times the rated charging power of the co...

Страница 40: ...roller will automatically cut off the output If the load reconnects the output automatically five times delay of 5s 10s 15s 20s 25s it needs to be cleared by pressing the Load button restarting the co...

Страница 41: ...y disconnection Charging LED indicator off during daytime when sunshine falls on PV modules properly Confirm that PV wire connections are correct and tight Battery voltage is lower than 8V Wire connec...

Страница 42: ...icator fast flashing When heat sink of controller exceeds 85 the controller will automatically cut off input and output circuit When the temperature below 75 the controller will resume to work System...

Страница 43: ...necessary Tighten all the terminals Inspect for loose broken or burnt wire connections Check and confirm that LED is consistent with required Pay attention to any troubleshooting or error indication...

Страница 44: ...A 20A 10A 20A 30A 40A 30A 40A 30A 40A Battery voltage range 8 32V 8 68V Max PV open circuit voltage 60V 46V 100V 92V 150V 138V MPP voltage range Battery voltage 2V 36V Battery voltage 2V 72V Battery v...

Страница 45: ...compensate coefficient 3mV 2V Default Grounding Common negative RS485 interface 5VDC 200mA RJ45 LCD backlight time Default 60S Range 0 999S 0S the backlight is ON all the time When lithium battery is...

Страница 46: ...g charging power mode is turned on Refer to P34 3 protection against solid objects protected against solids objects over 2 5mm 3 protected against sprays to 60 from the vertical Mechanical Parameters...

Страница 47: ...6AWG 16mm2 XTRA4215N Weight 0 57kg 0 96kg 1 31kg 1 70kg 2 07kg 2 47kg Certification Safety EN IEC62109 1 UL1741 CSA C22 2 107 1 EMC Emission immunity EN61000 6 3 EN61000 6 1 FCC 47 CFR Part 15 Subpart...

Страница 48: ...Conversion Efficiency Curves Illumination Intensity 1000W m2 Temp 25 C Model XTRA1206N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V Nominal System V...

Страница 49: ...45 Model XTRA1210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Страница 50: ...46 Model XTRA2206N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V Nominal System Voltage 24V...

Страница 51: ...47 Model XTRA2210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Страница 52: ...48 Model XTRA3210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Страница 53: ...49 Model XTRA4210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Страница 54: ...50 Model XTRA3215N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Страница 55: ...51 Model XTRA4215N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Страница 56: ...52 Model XTRA3415N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Страница 57: ...53 3 Solar Module MPP Voltage 68V 102V 119V Nominal System Voltage 36V 4 Solar Module MPP Voltage 68V 102V 119V Nominal System Voltage 48V...

Страница 58: ...54 Model XTRA4415N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Страница 59: ...55 3 Solar Module MPP Voltage 68V 102V 119V Nominal System Voltage 36V 4 Solar Module MPP Voltage 68V 102V 119V Nominal System Voltage 48V Any changes without prior notice Version number 4 2...

Страница 60: ...HUIZHOU EPEVER TECHNOLOGY CO LTD Beijing Tel 86 10 82894896 82894112 Huizhou Tel 86 752 3889706 E mail info epsolarpv com Website www epsolarpv com www epever com...

Отзывы: