background image

                   

                       

BEIJING EPSOLAR TECHNOLOGY CO., LTD.                                      Tel

+86-10-82894112 / 82894962    Website

www.epsolarpv.com/www.epever.com

 

1

                                                                                                                               

2

 

 

           
 

 

ViewStar AU series solar charge controller 

1. Overview                                                                                                       

 

Thank you for selecting the ViewStar AU series common positive solar charge 

controller. The VS-AU controller is a PWM charge controller with built in LCD display that 
adopts the most advanced digital technique. The multiple load control modes enable it can 
be widely used on solar home system, traffic signal, solar street light, solar garden lamp, 
etc. The features are listed below: 

  Adopt high quality components of ST,IR and Infineon, make sure product using lifespan 

  Terminals have UL and VDE certification, the product is more safer and more reliable 

  Controller can work continuously at full load within the environment temperature range 

from -25 to 55 

 

  3-Stage intelligent PWM charging

Bulk, Boost/Equalize, Float 

  Support 3 charging options: Sealed, Gel, and Flooded 

  LCD  display  design,  dynamically  displaying  device

’s  operating  data  and  working 

condition 

  Double USB design, the power supply charge for electronic equipment 

  With humanized button settings, operation will be more comfortable and convenient 

  Multiple load control modes 

 

  Energy statistics function 

  Battery temperature compensation function 

  Extensive Electronic protection 

2. Product Features                                                                                               

    

 

 

 

 

 

 

 

 

 

 

① 

LCD 

 

Battery Terminals 

② 

MENU Button 

 

Load Terminals 

③ 

RTS Port 

 

SET Button 

④ 

PV Terminals 

 

USB Output Ports

 

※ 

USB  output  ports  provide  the  power  supply  of  5VDC/2.4A  and  have  the  short 

circuit protection. 

 

 

 

 

NOTE:  Unplug  the  RTS,  the  temperature  of  battery  will  be  set  to  a  fixed 
value 25ºC.

 

3. Wiring                                                                                                                   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) Connect components to the charge controller in the sequence as shown above and pay 
much attention to the “+” and “-”. Please don’t insert the fuse or turn on the breaker during 
the installation. When disconnecting the system, the order will be reserved. 

(2)After  power  on  the  controller,  check  the  LCD  on.  Otherwise  please  refer  to  chapter 
6.Always connect the battery first, in order to allow the controller to recognize the system 
voltage. 

(3)The  battery  fuse  should  be  installed  as  close  to  battery  as  possible.  The  suggested 
distance is within 150mm. 

(4) The VS AU series is a positive ground controller. Any positive connection of solar, load 
or battery can be earth grounded as required. 

NOTE: Please connect the inverter or other load that it has the large start 
current to the battery rather than to the controller, if the inverter or other 
load is necessary. 

4. Operation                                                                                                             

4.1 Button Function 

Button 

Function 

MENU button 

  Browse interface 

  Setting parameter 

SET button 

  Load ON/OFF 

  Clear error 

  Enter into Set Mode 

  Save data 

4.2 LCD Display 

 

 Status Description 

Item 

Icon 

Status 

PV array 

 

Day 

 

Night   

 

No charging 

 

Charging 

 

PV Voltage, Current ,Power 

Battery 

 

Battery capacity, In Charging 

 

Battery voltage. current, temperature 

 

Battery type 

Load 

 

Load ON 

 

Load OFF 

 

Load Voltage, Current, Load mode 

 

Browse interface

 

NOTE

 

1)

 

When no operation, the interface will be automatic cycle, but the follow two interfaces 
not be display.

 

 

 

 

2

  Accumulative power zero clearing: Under PV power interface, press SET button and 

hold on 5s then the value blink, press SET button again to clear the value. 

3

  Setting temperature unit: Under battery temperature interface, press SET button and 

hold on 5s to switch.   

 

Fault Indication 

Status 

Icon 

Description 

Battery over 
discharged 

 

Battery level shows empty, battery frame blink, 
fault icon blink 

Battery over 
voltage 

 

Battery level shows full, battery frame blink, fault 
icon blink 

Figure 2 Connection diagram 

 

 

 

 
 

 

 
 

 

Figure 1 Characteristic 

 

 

 

 

 

 

 

 

 

 

 

 

Optional Accessory: 

Name: 

Remote Temperature Sensor 

Model:

 RTS300R47K3.81A 

Acquisition  of  battery  temperature  for  undertaking 
temperature  compensation  of  control  parameters,  the 
standard  length  of  the  cable  is  3m  (length  can  be 
customized). The RTS300R47K3.81A connects to the port 

  on the controller. 

 

 

Thank  you  for  selecting  ViewStar  AU  series  solar  charge 

controller.  Please  read  this  manual  carefully  before  using  the 
product.

 

 

Отзывы: